PQRM5300 33 Ux Ix xx xx (PS)
Error messages
Function
Sequence of operations 1. Log in the 7. Configurations menu
20201120-V1
Error
Explanation:
number:
21
Calibration values are demaged
22
User settings are demaged
23
Saved energies are demaged
Voltage dip:
The voltage value is less than 90% of nominal value.
(Not used the EN50160 standart)
Voltage interrupt:
The voltage value is less than 10% of nominal value.
(Not used the EN50160 standart)
Voltage swell:
The voltage value is more than 110% of nominal value.
110% t. (Not used the EN50160 standart)
Overload:
The measured current value is more than 120% of nominal
current value.
Phase sequence error:
The L1 L2 L3 phases follow each other unlike the positive
sequnce (-120°, -240°)
7.6. Clear errors
Here can the Supervisor delete the errors.
2. Choose the 7.6. Clear errors menu of the
7. Configurations menu with / buttons, and press
the ENTE switch.
3. Press the CLEAR switch
4. Press the BACK switch to exit from 7.6. Clear errors
submenu.