Operating menu
Additional information

Backup state

Navigation
Description

Comparison result

Navigation
Description
170
Meaning of the options
• Cancel
No action is executed and the user exits the parameter.
• Execute backup
A backup copy of the current device configuration in the HistoROM (built-in in the
device) is saved to the display module of the device.
• Restore
The last backup copy of the device configuration is copied from the display module to the
HistoROM of the device.
• Duplicate
The transmitter configuration is duplicated to another device using the transmitter
display module. The following parameters, which characterize the individual measuring
point are not included in the transmitted configuration:
Medium type
• Compare
The device configuration saved in the display module is compared to the current device
configuration of the HistoROM. The result of this comparison is displayed in the
Comparison result parameter (→  170).
• Clear backup data
The backup copy of the device configuration is deleted from the display module of the
device.
While this action is in progress, the configuration cannot be edited via the local
display and a message on the processing status appears on the display.
If an existing backup is restored to a different device using the Restore option, it may
occur that some device functionalities are no longer available. In some cases even a
device reset will not restore the original status.
In order to transmit a configuration to a different device, the Duplicate option should
always be used.
Setup → Advanced setup → Configuration backup display → Backup state
Displays which backup action is currently in progress.
 Setup → Advanced setup → Configuration backup display → Comparison result
Comparison between present device data and display backup.
Levelflex FMP50 PROFIBUS PA