L.B. White TS080 Owner's Manual And Instructions

L.B. White TS080 Owner's Manual And Instructions

Circulating tent heaters

Advertisement

Owner's Manual and Instructions
Circulating Tent Heaters
MODELS
OUTPUT (kW)
FUEL
Available in either
23.5
Propane Vapor
TS080
Withdrawal or
Natural Gas
Configurations
Congratulations!
You have purchased the finest tent heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any
suggestions or comments you may have...call us, at 608-783-5691.
ATTENTION ALL USERS
This heater has been designed and developed specifically for use as a direct-fired
circulating heater for tent heating applications. The heater has been evaluated by
Advantica Certification Services and found to conform to essential health and
safety requirements as required by the Gas Appliance Directive, Low Voltage
Directive, and Electromagnetic directive. If you are considering using this product
for any application other than its intended use, then please contact your local
agent, or contact L. B. White Co., Inc. in the U.S.A. at 608-783-5691.
150-26063

Advertisement

Table of Contents
loading

Summary of Contents for L.B. White TS080

  • Page 1 Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, at 608-783-5691.
  • Page 3 Save this Owner’s Manual for future use and reference. ■ Owner’s Manuals and replacement labels are available at no charge. For assistance, contact L.B. White at 608-783-5691. WARNING ■ Proper gas supply pressure must be provided to the inlet of the heater.
  • Page 4: Table Of Contents

    This manual will instruct you in the operation and care of your unit. Have your qualified installer review this manual The L.B. White Co., Inc. has a policy of continuous product with you so that you fully understand the heater and how it improvement.
  • Page 5: Heater Specifications

    Heater Specifications Model TS080 S S P P E E C C I I F F I I C C A A T T I I O O N N S S 23.5 Maximum Input (kW) Ventilation Air Required to Support Combustion (m...
  • Page 6: Fuel Information For Country Of Destination

    FUEL INFORMATION FOR COUNTRY OF DESTINATION Propane Gas Gas Category & Pressure Rate Destination Countries (mbar) (kg/hr) HU & NL (30) (36) BE, CH, CZ, ES, FR 1.68 (37) GB, IE, PT, SI & SK BE, CH, DE, ES & NL (50) (Butane) CY, CZ, DK, EE, FI,...
  • Page 7: Safety Precautions

    Safety Precautions W W A A R R N N I I N N G G Asphyxiation Hazard ■ This heater is intended for heating of tents with ■ Refer to the specification section of the heater’s temporary human occupancy. Do not use this heater Owner’s Manual, heater dataplate, or contact the L.B.
  • Page 8 2. All installations and applications of L.B. White heaters must meet all relevant local, regional and national 14. Direct spark ignition heaters will make up to three codes.
  • Page 9: Installation Instructions

    Contact your gas supplier or local dataplate and on page 4 of this manual. L.B. White agent if there are any questions. 4. The heater is designed for either indoor or outdoor 15. Check all connections for gas leaks using approved use.
  • Page 10 -- With the main burner in operation, check all or application. If you are in doubt, contact your local connections, hose connections, fittings and agent or the L.B. White Co., Inc. joints as well as the gas control valve inlet and outlet connections with approved gas leak 19.
  • Page 11: Heater Sizing Guidelines

    HEATER SIZING GUIDELINES 1. Multiply tent length x width x height = Cubic Meters EXAMPLE: (A). 1. Tent Length (15 meters) x width (15 meters) x height (4 meters) = 900 cubic meters (A). 2. Multiply (A) x .133 x 35 = (B). 2.
  • Page 12: Hose Hanger Assembly

    HOSE HANGER ASSEMBLY Align wire hose hanger to cage nuts on back of FIG. 1 heater. 2. Mount the hanger using the 1/4-20 x 3/4 in. bolts and 1/4 in. flat washers. Tighten securely. See Fig. 1. CAGE HOSE HANGER WASHER BOLT HOSE &...
  • Page 13: Duct Kit Assembly

    DUCT KIT ASSEMBLY Accessory Part # 08978 1. Extend duct kit to 3.65 m. length. FIG. 3 2. Insert tabs on adapter into slots at blower outler of heater. See Fig. 3. Push down to secure in place. SLOTS See below typical installation of heater located to exterior of tent.
  • Page 14: End Diffuser Assembly

    END DIFFUSER ASSEMBLY Accessory Part # 21177 1. Insert collar into duct. Tabs of collar must be facing 3. Insert tabs of collar into slots at air inlet of diffuser. away from duct. See Fig. 5. Push down to lock in place. 2.
  • Page 15: Start-Up Instructions

    Start-Up Instructions Follow steps 1 - 7 on initial start-up after heater installation 5. This heater includes a direct spark ignition (DSI) by a qualified gas heater service person. For normal start- control module for purposes of controlling the timing up, set thermostat above room temperature.
  • Page 16: Cleaning Instructions

    3. Regulators can wear out and function improperly. damaged markings must be replaced immediately by Have your gas supplier check the date codes on all contacting the L.B. White Co., Inc. Dataplates, start- regulators installed and check delivery pressures to up and shut-down instructions and warnings are the heater to make sure that the regulator is reliable.
  • Page 17: Service Instructions

    Service Instructions GENERAL 1. Close the fuel supply valve to the heater and WARNING disconnect the electrical supply before servicing B B u u r r n n H H a a z z a a r r d d unless necessary for your service procedure.
  • Page 18: Igniter And Flame Sensor

    IGNITER AND FLAME SENSOR IGNITER Disconnect the flame sensor lead from the ignition control. Remove the screws securing the mounting bracket to ■ the burner. See Fig. 11. Remove igniter assembly. The igniter and flame sensor should be cleaned to maintain proper ignition.
  • Page 19: Gas Pressure Checks

    GAS PRESSURE CHECKS C. Reading P P ressures WARNING Fire a a nd E E xplosion H H azard 1. With the heater operating, the pressure gauges should read the pressures specified on the dataplate. ■ Do not disassemble the gas control valve. ■...
  • Page 20: High Limit Switches

    TESTING THE MANUAL RESET HIGH LIMIT SWITCHES 4. Allow the switch cool down for about a minute before WARNING firmly pressing the reset button on the switch. Fire H H azard ■ Do not operate the heater with the high limit switch 5.
  • Page 21: Troubleshooting Guide

    Troubleshooting Guide Components should be replaced only after each step within WARNING the flow chart has been completed and replacement is Electrical Shock and Burn Hazard suggested in the flow chart. Refer to the Servicing sections as necessary to obtain information on disassembly and ■...
  • Page 26: Electrical Connection And Ladder Diagram

    Electrical Connection and Ladder Diagram CAUTION - REFER TO THE HEATER'S ELECTRICAL CONNECTION DIAGRAM WHEN SERVICING THE HEATER'S ELECTRICAL COMPONENTS TO AVOID WIRING ERRORS & EQUIPMENT MALFUNCTION. CHECK FOR PROPER OPERATION AFTER SERVICING. WARNING: THIS HEATER MAY START AT ANY TIME HIGH VOLTAGE IGNITION LEAD IGNITER GREEN/YELLOW...
  • Page 27: Heater Component Function

    Heater Component Function Air Proving Switch with Paddle Heat Chamber Safety device used to insure that the proper air flow is being Metal fire box that provides an area where burner flame achieved before the gas valve is opened. mixes with combustion air thereby providing heat. Burner High Limit Switch Cast iron component used to mix air and gas and provide an...
  • Page 28: Parts Schematic

    PARTS SCHEMATIC...
  • Page 29: Parts List

    PARTS LIST Item Description Part Number Regulator,Propane Gas,1/4 BSPT Inlet Propane Gas 23041 Regulator, Natural Gas 1/2 BSPT Inlet x 1/2 BSPT Outlet Natural Gas 23043 Hose, 12.7 mm ID x 3 m w/1/2 BSPT Male x M20 x 1.5 Male Adapters 21555 Base 571917...
  • Page 30: Warranty Policy

    L.B. White Co., Inc. will at its option, repair or replace the defective part or equipment, with a new part or equipment, F.O.B., Onalaska, Wisconsin.

Table of Contents