5.4 Connecting accessories
Fig. 16:
1 Multifunction connection X3
2 Adapter TCS
3 Accessory connection B1
4 Connection RS-485
Connecting pre-configured accessories
► Observe the installation instructions in the operating instructions for the relevant accessory.
► Note the existing configuration of existing connections and control lines.
► Connect only matching accessory devices to the electronic drive unit.
Using additional accessories
► Observe the installation instructions in the operating instructions for the relevant accessory.
► Note the existing configuration of existing connections and control lines.
► Use the Pfeiffer Vacuum display and control unit DCU 002, or a DCU with integrated power supply
5.5 Connecting the electrical supply
Risk of danger to life through missing mains disconnection device
The vacuum pump and electronic drive unit are not equipped with a mains disconnection device
(mains switch).
► Install a mains disconnection device according to SEMI-S2.
► Install a circuit breaker with an interruption rating of at least 10,000 A.
Installation and operation of accessories
Pfeiffer Vacuum offers a series of special, compatible accessories for its products.
● Information and ordering options for approved
pumps
can be found online.
Connecting accessory devices to the TC
● Use of Pfeiffer Vacuum accessories via the electronic drive unit is enabled via a corre-
sponding connection cable or adapter at the "X3" multi-function connection.
● The desired accessory output is configured via RS-485 using Pfeiffer Vacuum display
and control units or a PC.
1
X3
Example of accessory connection via adapter TCS 12
pack.
WARNING
2
3
4
7
6
5
Digital output DO2
6
Digital output DO1
7
Accessory connection A1
accessories for hybrid bearing turbo-
5
Installation