Pfeiffer Vacuum HiPace 30 Manuals
Manuals and User Guides for Pfeiffer Vacuum HiPace 30. We have
2
Pfeiffer Vacuum HiPace 30 manuals available for free PDF download: Operating Instructions Manual
Pfeiffer Vacuum HiPace 30 Operating Instructions Manual (116 pages)
Turbopump
Brand:
Pfeiffer Vacuum
| Category:
Water Pump
| Size: 8 MB
Table of Contents
Deutsch
3
Table of Contents
3
Gültigkeit
7
Mitgeltende Dokumente
7
Varianten
7
Zielgruppe
7
Konventionen
7
Anweisungen IM Text
7
Zu dieser Anleitung
7
Piktogramme
8
Aufkleber auf dem Produkt
8
Abkürzungen
9
Markennachweis
9
Abb. 1: Position der Aufkleber auf dem Produkt
9
Sicherheitshinweise
10
Sicherheit
10
Allgemeine Sicherheitshinweise
10
Sicherheitsmaßnahmen
14
Einsatzgrenzen des Produkts
15
Bestimmungsgemäße Verwendung
15
Vorhersehbarer Fehlgebrauch
16
Personenqualifikation
16
Personenqualifikation Sicherstellen
16
Personenqualifikation bei Wartung und Reparatur
17
Mit Pfeiffer Vacuum Weiterbilden
17
Rotorlager
18
Antrieb
18
Abb. 2: Aufbau Hipace
18
Kühlung
18
Funktion
18
Produktbeschreibung
18
Produkt Identifizieren
19
Produkttypen
19
Produktmerkmale
19
Lieferumfang
19
Transport und Lagerung
20
Transport
20
Lagerung
20
Installation
21
Vorbereitende Arbeiten
21
Hochvakuumseite Anschließen
22
Anforderungen für die Auslegung des Gegenflansches
22
Erdbebensicherheit Berücksichtigen
22
Abb. 3: Beispiel: Sicherheitsverbindungen
23
Dämpfungskörper Verwenden
23
Splitterschutz oder Schutzgitter Verwenden
23
Einbaulagen
24
ISO-KF Flansch an ISO-KF Befestigen
24
Abb. 4: Empfohlene Ausrichtung bei Verwendung Ölgedichteter Vorpumpen
24
Abb. 5: Flanschverbindung ISO-KF mit Spannring
24
ISO-K Flansch an ISO-K Befestigen
25
ISO-K Flansch an ISO-F Befestigen
25
Abb. 6: Flanschverbindung ISO-K zu ISO-K, Klammerschraube
25
Abb. 7: Flanschverbindung ISO-K mit ISO-F, Pratze und Gewindebohrung
25
Abb. 8: Flanschverbindung ISO-K mit ISO-F, Sechskantschraube und Gewindeboh
26
Abb. 9: Flanschverbindung ISO-K mit ISO-F, Stiftschraube und Gewindebohrung
26
Abb. 10: Flanschverbindung ISO-K mit ISO-F, Stiftschraube und Durchgangsbohrung
26
CF-Flansch an CF-F Befestigen
27
Abb. 11: Flanschverbindung CF-F, Sechskantschraube und Durchgangsbohrung
27
Abb. 12: Flanschverbindung CF-F, Siftschraube und Gewindebohrung
27
Vorvakuumseite Anschließen
28
Abb. 13: Flanschverbindung CF-F, Siftschraube und Durchgangsbohrung
28
Zubehör Anschließen
29
Abb. 14: Beispiel für den Vorvakuumanschluss an Hipace
29
Abb. 15: Beispiel für den Zubehöranschluss über Adapter TCS
29
Elektrische Versorgung Anschließen
30
Turbopumpe Erden
30
Abb. 16: Beispiel: Anschluss des Erdungskabels
30
Elektrischen Anschluss Herstellen
31
Abb. 17: Antriebselektronik mit Netzteil Verbinden
31
Betrieb
33
Inbetriebnahme
33
Betriebsarten
33
Betrieb über Feldbus
34
Betrieb über Pfeiffer Vacuum Steuergerät
34
Betrieb über Multifunktionsanschluss "X3
34
Betrieb über Anschluss "E74
34
Betrieb ohne Bedieneinheit
34
Turbopumpe Einschalten
35
Betriebsüberwachung
35
Betriebsanzeige über LED
35
Temperaturüberwachung
36
Ausschalten und Fluten
36
Ausschalten
36
Fluten
36
Wartung
38
Allgemeine Wartungshinweise
38
Wartungsintervalle Und- Zuständigkeiten
38
Betriebsmittelspeicher Austauschen
39
Betriebsmittelspeicher Demontieren
39
Betriebsmittelspeicher Montieren
40
Abb. 18: Betriebsmittelspeicher Demontieren
40
Antriebselektronik Austauschen
41
Abb. 19: Kapillarstäbe Einsetzen und Betriebsmittelspeicher Montieren
41
Antriebselektronik Demontieren
42
Antriebselektronik Installieren
42
Abb. 20: Demontage der Antriebselektronik
42
Drehzahlvorgabe Bestätigen
43
Abb. 21: Montage der Antriebselektronik
43
Außerbetriebnahme
44
Stillsetzen für Längere Zeit
44
Wiederinbetriebnahme
44
Recycling und Entsorgung
45
Allgemeine Entsorgungshinweise
45
Turbopumpe Entsorgen
45
Störungen
46
Servicelösungen von Pfeiffer Vacuum
48
Ersatzteile Hipace
50
Zubehör
51
Zubehörinformationen
51
Zubehör Bestellen
51
Technische Daten und Abmessungen
53
Allgemeines
53
Technische Daten
53
Abmessungen
55
EG Konformitätserklärung
57
Konformitätserklärung
58
English
59
About this Manual
63
Applicable Documents
63
Conventions
63
Instructions in the Text
63
Target Group
63
Validity
63
Variants
63
Pictographs
64
Stickers on Product
64
Abbreviations
65
Fig. 1: Position of the Stickers on the Product
65
Tbl. 1: Abbreviations Used in this Document
65
Trademark Proof
65
General Safety Information
66
Safety
66
Safety Instructions
66
Limits of Use of Product
70
Safety Precautions
70
Foreseeable Improper Use
71
Personnel Qualification
71
Proper Use
71
Tbl. 2: Permissible Ambient Conditions
71
Advanced Training with Pfeiffer Vacuum
72
Ensuring Personnel Qualification
72
Personnel Qualification for Maintenance and Repair
72
Cooling
73
Fig. 2: Hipace 30 Design
73
Function
73
Product Description
73
Rotor Bearing
73
Drive
74
Identifying the Product
74
Product Features
74
Product Types
74
Scope of Delivery
74
Storage
75
Transport
75
Transportation and Storage
75
Connecting the High Vacuum Side
76
Installation
76
Preparatory Work
76
Requirements for the Dimensioning of a Counter Flange
76
Consider Earthquake Protection
77
Tbl. 5: Requirements for the Dimensioning of Customer-Specific High Vacuum con
77
Fig. 3: Example: Safety Connections
78
Tbl. 6: Effect of Splinter Shield or Protective Screen on Pumping Speed
78
Using a Splinter Shield or Protective Screen
78
Using the Vibration Compensator
78
Fig. 4: Recommended Alignment When Using Oil-Sealed Backing Pumps
79
Fig. 5: Flange Connection ISO-KF to ISO-KF
79
Installation of ISO-KF Flange
79
Mounting Orientations
79
Attaching ISO-K Flange Onto ISO-K
80
Fig. 6: Flange Connection ISO-K to ISO-F, Bracket Screws
80
Installation of ISO-K Flange Onto ISO-F
80
Attaching CF Flange to CF-F
81
Fig. 7: Flange Connection CF-F, Hexagon Head Screw and through Hole
82
Fig. 8: Flange Connection CF-F, Stud Screw and Tapped Hole
82
Connecting the Fore-Vacuum Side
83
Fig. 10: Example of Fore-Vacuum Connection on Hipace
83
Fig. 9: Flange Connection CF-F, Stud Screw and through Hole
83
Connecting Accessories
84
Fig. 11: Example of Accessory Connection Via Adapter TCS
84
Connecting the Electrical Supply
85
Establishing Electric Connection
85
Fig. 12: Example: Connecting the Grounding Cable
85
Ground Turbopump
85
Fig. 13: Connecting Electronic Drive Unit to Power Supply Pack
86
Commissioning
87
Operation
87
Tbl. 7: Factory Setting of the Electronic Drive Unit for Turbopumps When Delivered
87
Operating Modes
88
Operation Via Connection "E74
88
Operation Via Field Bus
88
Operation Via Multi-Function Connection "X3
88
Operation Via Pfeiffer Vacuum Control Unit
88
Operation Without Operating Unit
88
Operating Mode Display Via LED
89
Operation Monitoring
89
Switching on the Turbopump
89
Switching off
90
Switching off and Venting
90
Tbl. 8: Behavior and Meaning of the Leds on the Electronic Drive Unit
90
Temperature Monitoring
90
Venting
90
Tbl. 9: Factory Settings for Delayed Venting in Turbopumps
91
General Maintenance Information
92
Maintenance
92
Maintenance Intervals and Responsibilities
92
Removing the Operating Fluid Reservoir
93
Replace Operating Fluid Reservoir
93
Assembling Operating Fluid Reservoir
94
Fig. 14: Removing the Operating Fluid Reservoir
94
Fig. 15: Insert Capillary Rods and Install Operating Fluid Reservoir
95
Replacing the Electronic Drive Unit
95
Fig. 16: Removal of Electronic Drive Unit
96
Installing Electronic Drive Unit
96
Removing Electronic Drive Unit
96
Confirming Speed Specification
97
Fig. 17: Assembling the Electronic Drive Unit
97
Tbl. 10: Characteristic Nominal Rotation Speeds of the Turbopumps
97
Decommissioning
98
Recommissioning
98
Shutting down for Longer Periods
98
Dispose of Turbopumps
99
General Disposal Information
99
Recycling and Disposal
99
Malfunctions
100
Tbl. 11: Troubleshooting Turbopumps
101
Service Solutions by Pfeiffer Vacuum
102
Fig. 18: Spare Parts Hipace
104
Spare Parts Hipace
104
Tbl. 12: Overview of the Spare Parts Available for the Hipace
104
Accessories
105
Accessory Information
105
Ordering Accessories
105
Tbl. 13: Accessories List
106
General
107
Technical Data
107
Technical Data and Dimensions
107
Dimensions
109
Fig. 21: Dimensions Hipace 30 | DN 40 ISO-KF
110
EC Declaration of Conformity
111
Declaration of Conformity
112
Advertisement
Pfeiffer Vacuum HiPace 30 Operating Instructions Manual (26 pages)
Brand:
Pfeiffer Vacuum
| Category:
Air Conditioner
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Manual
6
Validity
6
Applicable Documents
6
Variants
6
Target Group
6
Conventions
6
Instructions in the Text
6
Tbl. 1: Applicable Documents
6
Tbl. 2: Air Cooling Versions
6
Pictographs
7
Stickers on the Product
7
Tbl. 3: Stickers on the Product
7
Fig. 1: Position of the Sticker on the Product
7
Safety
8
General Safety Information
8
Safety Instructions
8
Safety Precautions
9
Product Usage Limits
9
Proper Use
9
Foreseeable Misuse
9
Tbl. 4: Permissible Ambient and Operating Conditions
9
Personnel Qualification
10
Product Description
11
Function
11
Identifying the Product
11
Scope of Delivery
11
Fig. 2: Layout of Air Cooling
11
Installation
12
Connecting the Air Cooling for 24 V DC
12
Fig. 3: Connecting the Air Cooling to Hipace 30, Hipace 80, Hipace 60 P and Split
12
Fig. 4: Connecting the Air Cooling to Hipace 300 with TC 110/TC 120
12
Fig. 5: Connecting the Air Cooling to Hipace 300 with TC 400
13
Fig. 6: Connecting the Air Cooling to Hipace 350 and Hipace 450
13
Connecting the Air Cooling for 115/230 V AC
14
Fig. 7: Connecting the Air Cooling to Hipace 400, Hipace 700 and Hipace 800
14
Connecting the Air Cooling for Hipace 60 P, Hipace 80, and Split
15
Fig. 8: Fitting the Mounting Bracket for Air Cooling
15
Fig. 9: Mounting the Air Cooling Onto the Bottom Part
15
Establishing Mains Connection
16
Connecting the Air Cooling, 24 V DC for Teletc
16
Fig. 10: Mains Connection
16
Fig. 11: Mounting the Air Cooling to the Electronic Drive Unit TC 400
16
Operation
18
Tbl. 5: Parameter Settings in the Electronic Drive Unit of the Turbopump
18
Service Solutions by Pfeiffer Vacuum
19
Technical Data and Dimensions
21
Technical Data
21
Flow 50/80
21
Dimensions
22
Tbl. 10: Air Coolings 115/230 V/AC
22
Fig. 12: Dimensions PM Z01 300 a | PM Z01 360 a | PM Z01 348
22
Fig. 13: Dimensions PM Z01 301 a | PM Z01 302 a | PM Z01 361 a | PM Z01 362 a
22
Fig. 14: Dimensions PM Z01 303 a | PM Z01 363 a
22
Fig. 15: Dimensions PM Z01 304 a | PM Z01 364 a
23
Fig. 16: Dimensions PM Z01 373 | PM Z01 374
23
Declaration of Conformity
24
Advertisement
Related Products
Pfeiffer Vacuum HiPace 60 P
Pfeiffer Vacuum HiPace 1500
Pfeiffer Vacuum HiCube 30 Eco
Pfeiffer Vacuum HiCube 300 Eco
Pfeiffer Vacuum HiCube 300 Classic
Pfeiffer Vacuum HiPace 300 P
Pfeiffer Vacuum HiCube 300 Pro
Pfeiffer Vacuum HiCube 300 H Pro
Pfeiffer Vacuum HIPACE 300 PLUS
Pfeiffer Vacuum HIPACE 30 NEO
Pfeiffer Vacuum Categories
Water Pump
Control Unit
Measuring Instruments
Industrial Equipment
Security Sensors
More Pfeiffer Vacuum Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL