Download Print this page

Landoll Brillion Turfmaker II Series Operator's Manual page 105

Advertisement

Electric Clutch
IMPORTANT
If your machine is equipped with an Electric Clutch at
no time use high pressure water or air to clean it, as
this can damage the unit.
Figure 5-17: High Pressure Warning
Acre Meter Troubleshooting
IMPORTANT
Acre Meter is dust and splash resistant, under no
circumstances should this unit be submerged in any
conductive, corrosive, or flammable liquid. At no time
use high pressure water or air to clean it, as this can
damage the unit. See Figure 5-17.
NOTE
The ground wire is for static discharge protection and has
no effect on the ability of the sensor to function properly
under normal conditions.
The battery operated Acre Meter uses 3 AA batteries. The
Acre Meter will display "LObat" when the batteries require
replacement. Remove the Acre Meter from the implement
and then the 4 Screws on the back of the case. See
Figure 5-18. Separate the housing from the rear plate.
Replace with 3 quality AA batteries.
Acre Meter does not count pulses during calibration
or does not count acres during operation.
1. Check the position of the Magnet Wheel Assembly
and Pick-Up Switch against the set-up instructions in
this manual. See "Acre Meter Kit, 5K275 - Optional"
on Page 2-16.
2. Verify that the magnet in the Magnet Wheel Assembly
has not come out.
3. Place the Acre Meter display in "Calibrate" mode by
pressing the *(FUNC) key until the "P-WORD"
indicator is lit and then press the up/down arrow keys
until the display shows 0 and the LED is blinking.
Break the connection between the display and the
Pick-Up Switch and short between pins A and B on
the display harness connector. You should see the
display increment +1 with each contact of the
connector terminals.
9K998-2306
TABLE OF CONTENTS
4. If step 3 works then wave a magnet in front of the
Pick-Up Switch face with it re-connected to the
display and see if the display increments up. If not, put
an ohm meter or continuity tester on the contacts of
the Pick-Up Switch Harness and place a magnet in
front of the Pick-Up Switch face. The Pick-Up Switch
should show continuity or near 0 ohms resistance.
Acre Meter cannot change the width or pulse count
settings or clear the field and total acres.
1. Check to see if a password needs to be entered by
pressing the *(FUNC) key until the "P-WORD"
indicator LED is lit. If "dIS" is displayed (password
disabled) no password is set.
2. If "Ent" is displayed a password must be entered to
change the settings or the password must be disabled
as instructed in the setup section of this manual.
Remove screws
to replace batteries
Acre Meter
Figure 5-18: Battery Replacement
5-11

Advertisement

loading