Statement Regarding The Vibration Emission - Norton clipper CM 352 Operating Instructions Manual

Table of Contents

Advertisement

VERS. 04.04.2019

2.5 Statement regarding the vibration emission

Declared value of vibration emission following EN 12096.
Machine
Model / code
CM 352
115V UK
70184607385
CM 352 230V
70184607386
The vibration value is lower and does not exceed 2.5 m / s.
Values determined using the procedure described in the standard EN 12418.
The measurements are made with new machines. Actual values may vary with site conditions, in terms
of:
 Materials worked
 Wear Machine
 Lack of maintenance
 Inappropriate tool for application
 Tool in poor condition
 Unskilled operator
 Etc...
The exposure time to vibration is based on the performance of work (related to the adequacy Machine /
Tool / worked material / operator)
When evaluating risks due to hand-arm vibration, you need to take into account effective usage at rated
power of machine during a full day of work; quite often you will realise that effective utilisation time
represents around 50% of overall duration of work. You have to consider, of course, breaks, water feeding,
preparation of work, time to move the machine, disk mounting...
Measured value of vibration
emission at m/s
2.2
Uncertainty K
2
2
m/s
0.5
MAN CM 352 EN
Tool used
Model / code
Clipper ALFA
11

Advertisement

Table of Contents
loading