VERS. 04.04.2019
2.5 Statement regarding the vibration emission
Declared value of vibration emission following EN 12096.
Machine
Model / code
CM 352
115V UK
70184607385
CM 352 230V
70184607386
The vibration value is lower and does not exceed 2.5 m / s.
Values determined using the procedure described in the standard EN 12418.
The measurements are made with new machines. Actual values may vary with site conditions, in terms
of:
Materials worked
Wear Machine
Lack of maintenance
Inappropriate tool for application
Tool in poor condition
Unskilled operator
Etc...
The exposure time to vibration is based on the performance of work (related to the adequacy Machine /
Tool / worked material / operator)
When evaluating risks due to hand-arm vibration, you need to take into account effective usage at rated
power of machine during a full day of work; quite often you will realise that effective utilisation time
represents around 50% of overall duration of work. You have to consider, of course, breaks, water feeding,
preparation of work, time to move the machine, disk mounting...
Measured value of vibration
emission at m/s
2.2
Uncertainty K
2
2
m/s
0.5
MAN CM 352 EN
Tool used
Model / code
Clipper ALFA
11