6.2. Submenu "Operation"

In this submenu you can do all the things that occur during operation of you layout:
Controlling vehicle and accessory decoders
Reading out and programme decoders
Checking feedback modules
Reading out and displaying system messages
Setting the model time
The explanations of the input fields are opened when you click on the symbol

6.2.1. Feedback

 Overview of all connected feedback devices (s88, CAN, BiDiB and LocoNet)
 Management and test of s88-, CAN- and LocoNet feedback modules
s88- (and CAN-) feedback modules
In this menu item, all feedback devices that generate simple occupancy messages are
recorded. Enter how many modules you have connected to the s88, CAN and LNet interface.
Otherwise, the feedback modules will not be taken into account in the evaluation of the busy
signals. A module with 16 inputs is considered to be one. Modules with fewer inputs (e.g. 8)
are evaluated proportionally (e.g. as ½ module).
You can also check the occupancy messages of the connected s88, CAN and LocoNet
feedback modules and thus detect faulty messages. Differences between the display and the
actual state of an input indicate problems with the data bus, errors on the feedback module or
on system parts connected to the feedback module.
You can set the type of display
static or dynamic
for one or more modules
BiDiB feedback modules
The list is limited to the display of BiDiB nodes that meet the occupancy class requirements
defined in the BiDiB specification.
The display of all BiDiB nodes including the representation of their assignment to the levels as
well as the listing of their properties can be found in the menu item "Operation / BiDiB". There
you also have the option to trigger an Identify command and to perform a reset. → Section
6.2.4
LNet
In this display field extended messages of LocoNet detectors are to be displayed that go
beyond simple occupancy messages. The display is not yet implemented (status: june 2022).