Display And Rgb-Leds - tams elektronik mc2 EasyControl Digital System Silver Edition Manual

Digital control unit
Table of Contents

Advertisement

6.1.2. Display and RGB-LEDs

Shown
in the display
0.0 to 6.5
St.
td
SH
ot
rE
St.
PA
IP|12|3.4|56.|78|9.1|23
Pf
6.2 | Operation with the mc²
Colour of the
RGB LEDs
green
red
green
red violet
flashing
yellow orange
red
flickering
blue flashing
+ white
swelling
blue circulating
no colour change
no colour change
red
Meaning
current current consumption [A]
The track voltage is switched on.
Stop. The track voltage is switched off.
"Test Drive". In test mode you can control
and test vehicle and accessory decoders
on the programming track with the virtual
control units HandControl.prog. and
FunctionControl.prog.
"Short Circuit" / short circuit during
operation.
Troubleshooting → section 8.2
"Overtemperature" / Overheating
Troubleshooting → Section 8.2
A reset is performed.
Stop / The track voltage is switched off.
If the STOP button was previously held longer, the
command for the BiDiB Identify for the mc² is sent.
Pairing. Control software is loaded for the
first time on a connected PC or mobile
terminal
IP address
The individual digits of the IP address are retrieved by
pressing the "GO" key several times. → Section 2
"Power failure". The input voltage is below
22 V. Disconnect the control unit from the
supply voltage immediately!
Troubleshooting → section 8.3