tams elektronik PZS-3 Manual

tams elektronik PZS-3 Manual

Shuttle-train control for analogue a.c. model railway layouts
Hide thumbs Also See for PZS-3:

Advertisement

Quick Links

Manual
PZS-3
Item no. 51-02035 | 51-02036 | 51-02037
Shuttle-train control
for analogue a.c. model railway layouts
tams elektronik
n n n

Advertisement

Table of Contents
loading

Summary of Contents for tams elektronik PZS-3

  • Page 1 Manual PZS-3 Item no. 51-02035 | 51-02036 | 51-02037 Shuttle-train control for analogue a.c. model railway layouts tams elektronik n n n...
  • Page 2: Table Of Contents

    8. Connecting the PZS-3..............24 8.1. Schema................24 8.2. Dividing the shuttle-train section into parts......25 8.3. Connecting the power supply..........25 8.4. Connecting the shuttle-train section to the PZS-3....27 9. Operation.................30 10. Programming the PZS-3.............33 11. Check list for troubleshooting.............36 12. Guarantee bond................38 13.
  • Page 3: Getting Started

    Any other use is inappropriate and invalidates any guarantees. The PZS-3 should not be assembled or mounted by children under the age of 14. Reading, understanding and following the instructions in this manual are mandatory for the user.
  • Page 4 English PZS-3 Checking the package contents Please make sure that your package contains:  one kit, containing the components listed in the parts list ( page 20) and one PCB or  one ready-built module or  one ready-built module in a housing (complete unit), ...
  • Page 5: Safety Instructions

    PZS-3 English 2. Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones.
  • Page 6 English PZS-3 Fire risk Touching flammable material with a hot soldering iron can cause fire, which can result in injury or death through burns or suffocation. Connect your soldering iron or soldering station only when actually needed. Always keep the soldering iron away from inflammable materials.
  • Page 7: Safe And Correct Soldering

    PZS-3 English In schools, training centres, clubs and workshops, assembly must be supervised by qualified personnel. In industrial institutions, health and safety regulations applying to electronic work must be adhered to. 3. Safe and correct soldering Caution: Incorrect soldering can cause dangers through fires and heat. Avoid these dangers by reading and following the directions given in the chapter Safety instructions.
  • Page 8 English PZS-3  To make a good soldering joint you must use a clean and unoxidised soldering tip. Clean the soldering tip with a damp piece of cloth, a damp sponge or a piece of silicon cloth.  Cut the wires after soldering directly above the soldering joint with a side cutter.
  • Page 9: Operation Overview

    PZS-3 English 4. Operation overview Traffic between two terminus stations The module controls the shuttle-train traffic between two terminus stations of an analogue a.c. model railway layout. At the second terminus station points can be connected. This allows the alternating traffic of two trains on the shuttle-train section.
  • Page 10 English PZS-3 Manual operation The halt at the terminus stations, the stops and the extra halts can be prolonged by connecting the corresponding input of the module to earth. Then the train stops at the next station, stop or halt as long as the input is connected to earth (at least so long as programmed for the particular halt).
  • Page 11 (e.g. lighting). When connecting the module to a transformer in use as driving transformer, short circuits occur within the PZS-3 which may damage it irreparably. The seperate supply of module and rails has the advantage that the driving voltage can be set individually.
  • Page 12 English PZS-3 Example for a shuttle-train traffic controlled by a PZS-3 In order to use the PZS-3 it is sufficient to connect the two terminus stations. All other extensions are optional. By connecting a second rail at terminus station 2 it is possible to run two trains alternatingly.
  • Page 13: Technical Specifications

    PZS-3 English 5. Technical specifications Caution: The PZS-3 must not be supplied via a transformer in use as a driving transformer! Further information see chapter 4. section "power supply". Supply voltage for the module 12 - 18 Volt d.c. or a.c. voltage Supply voltage a.c.
  • Page 14: Assembling The Kit

    English PZS-3 6. Assembling the kit You can skip this part if you have purchased a ready-built module or device. Preparation Put the sorted components in front of you on your workbench. The separate electronic components have the following special features...
  • Page 15 PZS-3 English Ceramic capacitors Among other things ceramic capacitors are used for filtering interference voltages or as frequency determining parts. Ceramic capacitors are not polarized. Normally they are marked with a three-digit number which indicates the value coded. The number 104 corresponds to the value 100 nF.
  • Page 16 English PZS-3 Light emitting diodes (LEDs) When operated in the forward direction the LEDs light. They are available in several different versions (differing in colour, size, form, luminosity, maximum current, voltage limits). Light emitting diodes should always be connected via a series resistor which limits the current and prevents failure.
  • Page 17 PZS-3 English Integrated circuits (ICs) Depending on the type, ICs fulfil various tasks. The most common housing form is the so-called "DIL"-housing, from which 4, 6, 8, 14, 16, 18 or more "legs" (pins) are arranged along the long sides.
  • Page 18 English PZS-3 Relays Relays are electronic switches, depending on their position the one or other (internal) connection is closed. The mode of operation of monostable relays can be compared to that of a push-button switch, i.e. the connection is only closed as long as the voltage is applicated.
  • Page 19 PZS-3 English PCB layout and parts list Note: The components R6 and JP1 shown on the layout, are not required for this application and thus do not need to be inserted. Page 19...
  • Page 20 English PZS-3 Resistors R21, R22, R33, R34 100 W R3, R12, R14, R15, R16 1,5 kW R2, R4, R5, R6, R10, R11, R13 4,7 kW R17, R18, R19, R31, R32 330 kW Trimm-pots R1, R29, R30 470 kW Diodes D1- D20 1N400x, x=2...7...
  • Page 21 PZS-3 English Assembly Proceed according to the order given in the list below. First solder the components on the solder side of the PCB and then cut the excess wires with the side cutter. Follow the instructions on soldering in section 3.
  • Page 22 English PZS-3 Rectifiers Observe the polarity! The pin connections are printed on the housing. The longer connecting pin is the positive pole. Electrolytic Observe the polarity! One of the two leads capacitors (the shorter one) is marked with a minus sign.
  • Page 23: Functional Test

    It is recommended to test the basic functioning of the module before installing it into the layout.  Connect a bulb to the connections 9 and 13 of the PZS-3.  Connect the two connections of the driving transformer to the module´s connections 3 and 11, the polarity is of no importance.
  • Page 24: Connecting The Pzs-3

    English PZS-3 8. Connecting the PZS-3 8.1. Schema Points, return line Supplying transformer PZS-3 Supplying transformer PZS-3 11 Driving transformer Driving transformer Switching input "extra halt(s)" Earth for switching and Outer conductor / all programming inputs sections Free section Points, switching contact 1...
  • Page 25: Dividing The Shuttle-Train Section Into Parts

    They can disturb the operation massively. 8.3. Connecting the power supply You can use a d.c. or an a.c. transformer with 12 to 18 V as a power supply for the PZS-3. The polarity is of no importance if you connect the PZC-3 only. Caution: When connecting several devices to the same transformer, all connections have to be polarized the same way as a rule.
  • Page 26 English PZS-3 Caution: Do not use the driving transformer for supplying the PZS-3! When supplying the circuit via a transformer used as a driving transformer, too, short circuits can occur that possibly damage the circtui irreparably. Hint: Driving transformers with an additional output for further accessories beside the driving controller are not suitable for supplying both rails and PZS, as they internally consist of one trafo only.
  • Page 27: Connecting The Shuttle-Train Section To The Pzs-3

    PZS-3 English 8.4. Connecting the shuttle-train section to the PZS-3 You must make at least the following connections (marked grey in the list):  Supplying transformer for the PZS-3 (s. section 8.3)  Driving transformer (s. section 8.3)  Terminus station 1 and 2 The other connections should be made only if required.
  • Page 28 English PZS-3 Page 28...
  • Page 29 PZS-3 English Additional connections Points at terminus station 2 return line: 1 switching contacts: In case you do not use stop-points you should connect an extra bistabile relais (not included in the package). See 14, 15 section "Connecting points". Switching input "prolonging the halting time"...
  • Page 30: Operation

    English PZS-3 In case you do not use stop-points you should connect an extra bistabile relais 12 V (or a relay circuit board RL-2) to the points. The bistable relais switches on the power supply for the one rail in terminus station 2 while switching off the power supply for the other rail.
  • Page 31 PZS-3 English If you want to integrate a second train into the shuttle-train service it has to be set onto the switched-off rail in terminus-station 2 with direction "terminus station 1" set. Immediately after switching on the power supply for the module, the shuttle-train traffic starts with a train starting from the terminus station 1 in direction of travel "way there".
  • Page 32 English PZS-3 Caution: The points´position and the "track busy"-status of the two rails in terminus station 2 are not controlled by the module. In case the points´position is altered externally a coming-in train possibly runs into occupied rails. Prolonging the halting time / Emergency stop By connecting the switching input "prolonging the halting time or...
  • Page 33: Programming The Pzs-3

    PZS-3 English 10. Programming the PZS-3 Programming the length of the phases is done the same way for the five different stops (two terminus stations, two stops, all extra halts). Carry out the programming steps 1 to 3 for all stops you want to program.
  • Page 34 English PZS-3 Programming step 2: Setting the phases´length By adjusting the trimmer you set the length of the phases accelerating, halt and braking for the 5 stops. In state of delivery the phases are set to the shortest possible length. Test the module with these settings first.
  • Page 35 PZS-3 English Programming step 3: Saving the settings After having set the phases´length for a stop at the trimmer, connect the programming input "save" (16) to earth (4) intermittently. N.B: Before closing the earth contact make sure the LED on the module flashes.
  • Page 36: Check List For Troubleshooting

    English PZS-3 11. Check list for troubleshooting  Parts are getting too hot and/or start to smoke. Disconnect the system from the mains immediately! Possible cause: one or more components are soldered incorrectly. à In case you have mounted the module from a kit, perform a visual check (à...
  • Page 37 PZS-3 English  Possible cause: The locomotive has a decoder with automatic recognition of the analogue mode. Principally these locomotives are not suitable for operation with the shuttle-train control. Hotline: If problems with your module occur, our hotline is pleased to help you (mail address on the last page).
  • Page 38: Guarantee Bond

    English PZS-3 12. Guarantee bond For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first...
  • Page 39: Eu Declaration Of Conformity

    This product conforms with the EC-directive 2012/19/EG on waste electrical and electronic equipment (WEEE). The Tams Elektronik GmbH is registered with the WEEE-no. DE 37847206, according to. § 6 sect. 2 of the German electro regulations from the responsible authority for the disposal of used electro equipment.
  • Page 40 Information and tips: http://www.tams-online.de Warranty and service: Tams Elektronik GmbH Fuhrberger Straße 4 DE-30625 Hannover fon: +49 (0)511 / 55 60 60 fax: +49 (0)511 / 55 61 61 e-mail: modellbahn@tams-online.de...

This manual is also suitable for:

51-0203551-0203651-02037

Table of Contents