Electromagnetic Interference (EMI) Susceptibility
Conducted
1
Susceptibility
ESD Failure Level
1
Limits
Table 23 ESD Failure
Level Limits
70
The transient voltage is the actual peak voltage above the normal
AC voltage from the power source.
The voltage limits for power and data cables are:
• 2 kV S/W recoverable errors
• No hardware failures
The power cable voltage limits are:
• 2.0 kV common mode (no errors allowed)
• 1.0 kV differential mode (S/W recoverable errors, no hardware
failure)
Note: Maximum energy in a single pulse from the transient
generator must be limited to 2.5 W.
This section lists the ESD failure level limits for normal operator
access areas.
Failure
Type
Equipment
Hardware
Office
Hardware
Office
Quantum|ATL PowerStor L200 Series Library User's Guide
Failure
Level
Allowable Errors
to 12 kV
No operator intervention (soft
recoverable errors allowed)
to 15 kV
No component damage -
operator intervention allowed
(soft and hard errors allowed)