Emissions

8.1.2 Conducted Emissions

The tape drive meets the conducted emissions limits per CISPR 22: 1997 listed in

Table 8-2. Conducted Emissions Limits

Frequency Range
a. The limit decreases with the logarithm of the frequency.

8.1.3 Harmonic Current Emissions

The tape drive meets this standard: EN 61000–3–3: 1995, Limitation of voltage fluctuations and
flicker in low-voltage supply systems for equipment with rated current up to and including 16A.
Table 8-3
lists the odd harmonic limits for Class A equipment. The harmonics of the input current do
not exceed the maximum permissible values given in this table multiplied by a factor of 1.5.

Table 8-3. Odd Harmonic Limits for Class A Equipment Limits

8-2
(MHz)
0.15 to 0.50
0.50 to 5
5 to 30
Harmonic Order
(n)
3
5
7
9
11
13
15 <= n <= 39
Quasi–peak
a
66 to 56
56
60
Maximum Permissible Harmonic Current
September 2004
DLT VS160 Product Specification
Table
Limits
dB(µV)
Average
56 to 46
46
50
(A)
2.3
1.14
0.77
0.40
0.33
0.21
0.15 x (15/n)
81-81275-01 REV A02