Quantum PowerStor L200 Series User Manual page 91

Quantum powerstor l200: user guide
Hide thumbs Also See for PowerStor L200 Series:
Table of Contents

Advertisement

OCP Display
CUP FAILED! CUP
Timeout
CUP FAILED
Incidental
Ldr/Drv Timeout In
Retry
Loader Timeout
In Retry
Prepos Timeout
In Retry
** Ldr Err<xx>***
Attention Needed
Elevator Move
Failed
Cart Failed to
Eject
Quantum|ATL PowerStor L200 Series Library User's Guide
Description
The requested code update
operation failed and the unit timed
out during the code update process.
The requested code update
operation was aborted due to a
failure of a preliminary
operation:drive communication
failure or timeout.
CHM failed to move the cartridge
into the drive.
Drive failed to load the cartridge.
The command aborted after the
maximum number of retries was
exceeded.
The command aborted after
maximum number of retries was
exceeded trying to preposition the
CHM.
An error code xx was returned from
the loader. If the command was
severe, the doors will unlock and
is appended to
Attention Needed
the error message.
Unable to preposition elevator at
drive during an unload cartridge
operation.
Drive did not eject cartridge when
commanded to do so.
Appendix B Error Messages and Definitions
Recommended Operator Action
Retry the operation.
If the operation fails again, contact
an authorized field service engineer.
Cycle the library power and try the
operation again.
If the operation fails again, contact
an authorized field service engineer.
Error code descriptions are listed in
Library Error Definitions
page 76.
Retry the operation.
If the operation fails again, contact
an authorized field service engineer.
on
75

Advertisement

Table of Contents
loading