Quantum PowerStor L200 Series User Manual page 90

Quantum powerstor l200: user guide
Hide thumbs Also See for PowerStor L200 Series:
Table of Contents

Advertisement

Appendix B Error Messages and Definitions
OCP Display
Prepare slot <n> to
receive cart
Cartridge fault Rem
Extra carts
Cartridge fault
Homeless
Cart fault Homeless
Drv <n> In Flux
Drv <n> HwError
Door Unlocked!
LDR ERR: <x>
DLC ERR: <x>
DRIVE ERROR!
LoadFirstCart
FAILED
Cleaning FAILED
CLN slot Empty
CLN Tape Expired
NOT a CLN Tape
74
Description
There are too many cartridges in the
library.
No slot available for a cartridge in
the drive.
These error messages appear when
the OCP is used to initiate a system
test routine. Each message indicates
a reason why the test can not be
initiated.
The error code was returned by the
loader process.
An error occured communicating
with the tape drive.
Occurs when the
Autoload Cart
command is set and there is no
cartridge to load.
The attempted cleaning cycle failed. Check for:
A cleaning cartridge was not found
in the required slot 7.
The cleaning cycle was not
completed because the cleaning
cartridge has expired.
The cartridge in the cleaning slot is
not a cleaning cartridge.
Quantum|ATL PowerStor L200 Series Library User's Guide
Recommended Operator Action
Open the door and empty a
magazine slot by removing a
cartridge.
Correct problem and retry.
Error code descriptions are listed in
Library Error Definitions
page 76.
• A valid cleaning cartridge is in
the required slot
• The cleaning cartridge has not
expired
Insert cleaning cartridge in slot 7
and retry the operation.
Replace the cleaning cartridge.
Insert a cleaning cartridge in the
cleaning slot.
on

Advertisement

Table of Contents
loading

Table of Contents