Chapter 13: Error Messages
Terminal Interface Messages
Action: Verify the register state is as expected, if so, you may continue with no
further action. If not, reset the emulator from the emulation system.
148
cf int7 must be lev if cf im=nor
Cause: The target system interrupt mode is set to normal, so there is no such thing
as IRQ7.
Action: Either make interrupt 7 level sensitive or configure the emulator for the
dedicated interrupt mode.
149
Register modify would cause chip select address decode conflict
Cause: The chip select register modification you just attempted would cause two or
more chip selects to be enabled and overlap.
150
bar register must not map internal memory to 0
Cause: If internal memory were mapped to 0, the vector table along with the BAR
and SCR registers would be overwritten.
151
HP 64170A has missing memory module:
bank <bank number>
Action: Make sure the HP 64170 memory board has at least one memory module
installed in bank 0. It is not required for bank 1 to have a memory module. This
must be corrected for the emulator to function correctly.
An example showing an empty bank (bank 1), viewed with the Terminal Interface
ver command, is:
HP 64746 (PPN: 64746A) Motorola 68302 Emulator
152
HP 64170A has mixed memory modules:
banks 0, <bank number>
Cause: The memory modules loaded on the memory board can be 256 Kbyte
modules or 1 Mbyte modules, but not a combination of both types. Mixing the two
508
Version:
A.00.03 24Jun91
Control:
HP64170A Memory Control Board
Memory:
0 KBytes
Bank 0:
HP64171A/C 256 KByte Memory Module
Bank 1:
Empty
Bank 2:
Empty
Bank 3:
Empty