HP 64746 User Manual page 517

Emulation/analysis
Table of Contents

Advertisement

636
Register not writable: %s
Cause: This error occurs when you attempt to modify a read only register.
Action: If this error occurs, you cannot modify the contents of the register with the
modify register command.
637
Register class cannot be modified: %s
Cause: You tried to modify a register class instead of an individual register.
Action: You can only modify individual registers. Refer to the display registers
command description for a list of register names.
640
Unable to reset
Cause: Target condition or system failure.
Action: Check target system, and run performance verification (Terminal Interface
pv command).
650
Unable to configure break on write to ROM
Cause: The emulator controller is unable to configure for breaks on writes to
ROM, possibly because the emulator was left in an unknown state or because of a
hardware failure.
Action: Initialize the emulator or cycle power. Then reenter the command. If the
same failure occurs, call your HP sales and service office.
651
Unable to configure break on software breakpoints
Cause: The emulator controller cannot enable breakpoints, possibly because the
emulator is in an unknown state or because of a hardware failure.
Action: Initialize the emulator or cycle power, then re-enter the command. If the
same failure occurs, call your HP sales and service office.
653
Break condition configuration aborted
Cause: Occurs when <CTRL>c is entered during the configuration of break
conditions.
Chapter 13: Error Messages