Fastlane
Pro Swim Unit Installation
®
The threaded rods MUST be tied into the pools bonding grid. Secure a bonding clamp to each threaded
rod. Attach a #8 solid copper wire to each bonding clamp. These wires MUST be attached to a bonding
connection that's incorporated into the pool's bonding grid. In most cases this will be a connection at the
rebar. Verify ALL bonding connections are tight before shooting gunite (Fig. 4.4).
Fig. 4.4
Prior to shooting gunite, it is critical that the opening of each thru-wall and the threaded rods that extend
into the finished pool be covered. No gunite can be embedded in these areas.
After verifying the bracket is positioned, bonding connections are secure, and thru-wall openings/threaded
rods are covered, gunite can be shot (Fig. 4.5).
Fig. 4.5
.