Section 7
WALL MOUNT FASTLANE PRO INSTALLATION
7.1 Fill the pool up to operating level. The water level should be approximately 1-1/2 (38mm) below the
W
threaded rods/threaded installed in the pool wall. Apply Teflon sealant to the threads of each bushing
reducer and then thread them into the thru-wall fittings. Apply Teflon sealant to the threads of the liquid
tight fittings and then thread them into the bushing reducers (Fig. 7.1).
Fig. 7.1
7.2 With a minimum of two people, carefully lower the Fastlane Pro into the pool. Align the mounting hole
at the top of each hat section with the corresponding threaded rod/stud to hang the swim unit. Feed the
two hydraulic sub hoses into the liquid tight fittings and into the conduit behind the pool wall. Once
routed through the conduit, tighten the compression glands of the liquid tight fittings (Fig. 7.2).
If a junction box is being employed, attach the sub hoses to the run hoses in the junction box using the
adapters included in the run hose kit. If there is no junction box, then the sub hoses from the Fastlane
Pro will be attached directly to the Hydraulic Power Unit.
7.3 The next step is bonding the Fastlane Pro. On the left side of the swim unit, attach the bonding wire
from the grab bar to the threaded rod/stud. On the right side of the unit, attach the bonding wire,
pre-attached to the swim unit, to the threaded rod/stud. IT IS CRITICAL THAT THE BONDING
WIRES ARE ATTACHED PROPERLY. Once bonding wires are secured, use the provided lock
washers and jam nuts to secure the Fastlane Pro to the pool wall (Fig. 7.2). Once the unit is fully
mounted, the top lid can be attached to the housing (see Fig. 6.4).
Jam Nut
Fig. 7.2
Hat Section
Bonding Wire
from Grab Bar
Flat Washer
Threaded Rod
Lock Washer
Sub Hoses
Mounting Kit
(gunite shown)
Thru-Wall Fi ing
Bushing Reducer
Liquid Tight Fi ing
Fastlane
Pro Swim Unit Installation
®
Bonding Wire
from Fastlane
Pro Assembly
30