Fastlane
Pro Swim Unit Installation
®
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal
body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase
in the internal temperature of the body. The effects of hyperthermia include. L'hyperthermie se produit lorsque la
température interne du corps atteint un niveau supérieur de plusieurs degrés à la température corporelle normale de
37 °C (98.6 °F). Les symptômes de l'hyperthermie comprennent la somnolence, la léthargie et une augmentation de
la température interne du corps. Les effets de l'hyperthermie comprennent.
a) unawareness of impending hazard/ méconnaissance d'un danger imminent.
b) failure to perceive heat/ incapacité à percevoir la chaleur.
c) failure to recognize the need to exit spa/ incapacité à reconnaître la nécessité de quitter le spa.
d) physical inability to exit spa/ incapacité physique de quitter le spa.
e) fetal damage in pregnant women/ dommages foetaux chez les femmes enceintes.
f) unconsciousness and danger of drowning/ inconscience et danger de noyade.
Suction Outlet Fitting Assembly (SOFA) Safety Instructions
When installing and using this equipment, basic safety precautions shall always be followed including the following
IMPORTANT SAFETY INSTRUCTIONS.
WARNING: Any modification that increases the flow rate of the circulation system shall require re-evaluation of the
cover/grate and sump to ensure that the flow rating of the suction outlet fitting assembly (SOFA) is not
exceeded.
WARNING: Missing, broken, or cracked cover/grates, sumps, mud frames, or any other SOFA Component shall be
replaced before bathers are allowed to use the pool.
WARNING: Loose cover/grates shall be reattached before bathers are allowed to use the pool.
Suction Outlet Fitting Assembly (SOFA) User Maintenance Instructions
Field Modifications:
Any field modification made to the SOFA not authorized by Endless Pools installation instructions shall void the SOFA
certification.
Configuration Modifications:
No modification shall be made to a SOFA structure or flow path unless the new configuration has been certified as a
new SOFA.
Service Life:
The SOFA is constructed of 316L perforated stainless steel. It shall be replaced after 25 years of use using a #2 Phillips
head screwdriver. The SOFA shall be replaced at or before the end of the service life. The service life of the SOFA
begins the month and year in which the SOFA is installed with or without water.
Service Instructions:
If service is required to inspect, repair, or replace the SOFA, it shall be done so with a #2 Phillips head screwdriver.
DO NOT USE POWER TOOLS TO INSTALL FASTENERS. Start installation of screws by hand to ensure proper thread
engagement and to prevent cross threading. REFER TO "SUCTION OUTLET FITTING SERVICE INSTRUCTIONS" FOR
ANY SERVICE REQUIRED TO REPAIR OR REPLACE ANY SOFA COMPONENT OR FASTENER.
1.
Hand check the SOFA after installation to verify that it's snug.
2. Before each use, verify the SOFA including the fasteners, are undamaged and have not been tampered with.
3. Any missing, broken, or cracked SOFA shall be replaced before using.
4. A loose SOFA and associated components shall be reattached before using.
5. The SOFA components and fastener receptacles shall be clean and free of debris or obstructions during the
installation.
5
SAVE THESE INSTRUCTIONS
CONSERVEZ CES INSTRUCTIONS
Need help?
Do you have a question about the FASTLANE PRO and is the answer not in the manual?
Questions and answers