Toshiba vlp technology P9 ASD Installation & Operation Manual page 154

Hide thumbs Also See for vlp technology P9 ASD:
Table of Contents

Advertisement

F343
Panel Torque Bias
Program Torque Torque Control
Once enabled at parameter F341, this parameter establishes the torque bias
setting to which the setting of
produce the final torque value used to carry out the Braking Mode Selection
function of parameter F341.
Panel Torque Gain
Program Torque Torque Control
Once enabled at parameter F341, this parameter sets the sensitivity of the
torque control source selected at
function of parameter F341.
Release Time
Program Torque Torque Control
Once enabled at parameter F341, this parameter sets the time that the brake will
hold after the requirements of the Braking Mode Selection function of
parameter
F341
have been met.
Creeping Frequency
Program Torque Torque Control
Once enabled at parameter F341, and while running, upon receiving a Stop
command this parameter sets an output frequency to be provided for the
duration of the time setting of parameter F347.
Creeping Time
Program Torque Torque Control
Once the Creep function of
duration of activation of the Creep function.
146
F342
will either add to or subtract from to
F342
for the Braking Mode Selection
F346
is activated, this parameter determines the
Direct Access Number — F343
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — -250.00
Maximum — +250.00
Units — %
Direct Access Number — F344
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 100.00
Units — %
Direct Access Number — F345
Parameter Type — Numerical
Factory Default — 0.05
Changeable During Run — Yes
Minimum — 0.00
Maximum — 2.50
Units — Seconds
Direct Access Number — F346
Parameter Type — Numerical
Factory Default — 3.00
Changeable During Run — Yes
Minimum — F240 Setting
Maximum — 20.0
Units — Hz
Direct Access Number — F347
Parameter Type — Numerical
Factory Default — 0.10
Changeable During Run — Yes
Minimum — 0.0
Maximum — 2.50
Units — Seconds
P9 ASD Installation and Operation Manual