The setting target can be checked with [Source Device] display, [Terminal] display and [Sensor]
display.
Perform the settings shown in the following table and then click on the [Set] button.
Setting Item
Baud Rate
[Baud Rate] addition ratio
combo box
Data Length
Parity
Stop Bits (Stop Bit Length)
Buffer Size
Time Out
Checksum
Subsystem
Primary/Secondary
Sentence
Section 17 Adjusting and Setting up Equipment (for Services)
Description of Setting
Select the baud rate of the serial port on the
combo box.
In the [Detail] dialog of any of CH8 to CH10, the
[Baud Rate] addition ratio combo box is
displayed on the right side of the [Baud Rate]
combo box.
Displayed in the [Detail] dialog of CH8 to CH10.
By using this combo box, the addition ratio (%)
for adjusting the baud rate can be changed. The
baud rate is determined by adding the additional
ratio to the value that is set in the [Baud Rate]
combo box.
Example)4800 × (1 + 1.5 / 100) = 4872
Additional ratio
Select the data length of the corresponding serial
port from the combo box.
Select the parity of the corresponding serial port
from the combo box.
Select the stop bit length of the corresponding
serial port from the combo box.
Enter the buffer size of the corresponding serial
port from the list.
Enter the time-out duration of the corresponding
serial port from the list.
Select the check box and enable the checksum
of the sentence of the corresponding serial port.
Set the equipment to be connected for Alert
Handling.
Displayed only when the sensor is "Alert (from
Subsystem)" or "Alert (to CAM)".
The selection is also allowed for the subsystem
that has already been used in the channel of
some other serial port.
Select Primary or Secondary for IAS (MODBUS)
input.
Displayed only when the sensor is
"IAS(MODBUS)".
Select the sentence of Alert Handling.
Displayed when the sensor is other than "Alert
(BNWAS), "IAS(MODBUS)", or "DSC" or
"NAV/Alert".
17-16
Setting Value
Selectable baud rates vary
depending on the serial port
(refer to "Selectable baud
rates").
0.0% to 3.0% (can be set in
the unit of 0.5%)
5/6/7/8
None/Odd/Even
1/2
0 to 10240 byte
0 to 999s
To enable: Select.
To disable: Clear.
"Alert (from Subsystem)":
Equipment that is set as
-/installed (Task Station and
sensor)
"Alert(to CAM)":
Equipment that is set as
-/installed (Task Station)
Primary: Primary system
Secondary: Secondary
system
Normal sensor such as GPS
and Log:
-/ALR/ALF
"Alert (from Subsystem/to
CAM)":
ALR/ALF

Advertisement