Message
DSC(Communication
failed, Sub LAN)
DSP(Heading Data)
Dual Axis SOG(invalid)
Dual Axis SOG(not
plausible)
Dual Axis
SOG(unavailable)
Echo Sounder #n
(Communication failed,
Direct)
Echo Sounder #n
(Communication failed,
Main LAN)
Echo Sounder #n
(Communication failed,
Sub LAN)
Engine Telegraph #n
(invalid)
Engine Telegraph #n
(not plausible)
Engine Telegraph #n
(unavailable)
Engine/Propeller #n
(invalid)
Engine/Propeller #n (not
plausible)
Engine/Propeller #n
(unavailable)
e-Token(Communication
error)
Appendix A Alert, Maintenance INFO and Permanent information
Explanation
Communication with DSC
cannot be performed via
Sub LAN.
There is an error in the
heading data received by
DSP.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
Communication with Echo
Sounder cannot be
performed via Serial.
Communication with Echo
Sounder cannot be
performed via Main LAN.
Communication with Echo
Sounder cannot be
performed via Sub LAN.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
There is an error in
communication with
e-Token.
Advice
Check the condition of DSC and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Check the condition of Echo Sounder and
Serial.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Echo Sounder and
Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Echo Sounder and
Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Restart the device.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.