Download Print this page

JRC JAN-7201S Instruction Manual page 186

Simple ecdis
Hide thumbs Also See for JAN-7201S:

Advertisement

Message
TXRX(PS)
TXRX(Trigger)
TXRX(Video)
VDR(Communication
failed, Main LAN)
VDR(Communication
failed, Sub LAN)
Water
Thermometers(Commun
ication failed, Main LAN)
Water
Thermometers(Commun
ication failed, Sub LAN)
Wind(invalid)
Wind(not plausible)
Wind(unavailable)
Appendix A Alert, Maintenance INFO and Permanent information
Explanation
The power supply circuit in
the radar antenna is
abnormal.
There is possibility that
timing reference signals
are not normally output
from the radar antenna.
There is possibility that
radar image signals are
not normally output from
the radar antenna.
Communication with VDR
cannot be performed via
Main LAN.
Communication with VDR
cannot be performed via
Sub LAN.
Communication with
Water Thermometer
cannot be performed via
Main LAN.
Communication with
Water Thermometer
cannot be performed via
Sub LAN.
There is a format error or
a status error of the Wind
data.
There is a range error of
Wind data.
The Wind data cannot be
received.
Advice
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Check the condition of VDR and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of VDR and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Water Thermometer
and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Water Thermometer
and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
A-40

Advertisement

loading

This manual is also suitable for:

Jan-9201s