Download Print this page

JRC JAN-7201S Instruction Manual page 168

Simple ecdis
Hide thumbs Also See for JAN-7201S:

Advertisement

Message
Anemometer(Communic
ation failed, Main LAN)
Anemometer(Communic
ation failed, Sub LAN)
Autopilot(Communicatio
n Failed, Main LAN)
Autopilot(Communicatio
n Failed, Sub LAN)
Autopilot malfunction
Autopilot(Invalid)
Autopilot(Not Plausible)
Autopilot(Unavailable)
Azimuth Thruster
#n(invalid)
Azimuth Thruster #n(not
plausible)
Azimuth Thruster
#n(unavailable)
Blizzard(Process Error)
Blizzard(SYNC Signal
Lost)
Appendix A Alert, Maintenance INFO and Permanent information
Explanation
Communication with
Anemometer cannot be
performed via Main LAN.
Communication with
Anemometer cannot be
performed via Sub LAN.
Communication with
Autopilot cannot be
performed via Main LAN.
Communication with
Autopilot cannot be
performed via Sub LAN.
AP equipment error
There is a format error or
a status error of the
Autopilot data.
There is a range error of
Autopilot data.
The Autopilot data cannot
be received.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
The control circuit in the
radar antenna is
abnormal.
ASIC for radar detected
an error in an interrupt
signal.
Advice
Check the condition of Anemometer and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Anemometer and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Autopilot and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Autopilot and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Turn off the power of the device and request
the distributor to repair.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the device.
A-22