Download Print this page

JRC JAN-7201S Instruction Manual page 182

Simple ecdis
Hide thumbs Also See for JAN-7201S:

Advertisement

Message
Sea TEMP(invalid)
Sea TEMP(unavailable)
Ship's
clock(Communication
failed, Main LAN)
Ship's
clock(Communication
failed, Sub LAN)
S-J I/O <->
AP(Communication
error)
S-J I/O Time Out
S-J I/O(Unit failure)
S-JOY <-> S-J
I/O(Communication
error)
S-JOY(Unit failure)
SLC1 - #n
(Communication failed,
Main LAN)
SLC2- #n
(Communication failed,
Sub LAN)
Stbd Main
Propeller(invalid)
Appendix A Alert, Maintenance INFO and Permanent information
Explanation
There is a format error or
a status error of the Water
temperature data.
The Water temperature
data cannot be received.
Communication with
Ship's clock cannot be
performed via Main LAN.
Communication with
Ship's clock cannot be
performed via Sub LAN.
S-JOY detected a
communication error with
AP.
A communication error
with S-JOY was detected.
An error occurred in the
S-JOY unit.
S-JOY detected a
communication error with
S-JOY I/O.
An error occurred in the
S-JOY equipment.
Communication with
SLC1-#n cannot be
performed via Main LAN.
Communication with
SLC2-#n cannot be
performed via Sub LAN.
There is a format error or
a status error of the data.
Advice
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Check the condition of Ship's clock and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Ship's clock and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check AP.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check S-JOY.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Turn off the power of the device and request
the distributor to repair.
Turn off the power of the device and request
the distributor to repair.
Turn off the power of the device and request
the distributor to repair.
Check the condition of SLC1-#n and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of SLC2-#n and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the sensor condition.
A-36