Message
PROC(AZI)
PROC(HL)
PROC(Interrupt#n)
PROC(Trigger)
PROC(Video)
RADAR PROC(Data)
RIF(Communication
error)
ROT(invalid)
ROT(unavailable)
RTC Abnormal
Rudder #n(invalid)
Rudder #n(not plausible)
Rudder #n(unavailable)
Rudder(Communication
failed, Main LAN)
Rudder(Communication
failed, Sub LAN)
Explanation
An azimuth signal error
has occurred at the signal
processing unit.
A heading line signal error
has occurred at the signal
processing unit.
There is a stern interrupt
error in the signal
processing unit.
A trigger signal error has
occurred at the signal
processing unit.
A radar image signal error
has occurred at the signal
processing unit.
Control of radar
signal/image processing
failed.
There is an error in
communication with RIF.
There is a format error or
a status error of the ROT
data.
The ROT data cannot be
received.
RTC is abnormal.
There is a format error or
a status error of the
Rudder data.
There is a range error of
Rudder data.
The Rudder data cannot
be received.
Communication with
Rudder cannot be
performed via Main LAN.
Communication with
Rudder cannot be
performed via Sub LAN.
A-35
Appendix A Alert, Maintenance INFO and Permanent information
Advice
Turn off the power of the device and check the
connection of the equipment cable.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Turn off the power of the device and check the
connection of the equipment cable.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Turn off the power of the device and check the
connection of the equipment cable.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Turn off the power of the device and check the
connection of the equipment cable.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Restart the power.
If it cannot be recovered after three times of
restart, contact the distributor.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Check the condition of Rudder and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Rudder and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
APP A
23
24
25

Advertisement

loading

This manual is also suitable for:

Jan-9201s