Message
Bow Azimuth Thruster
#n (not plausible)
Bow Azimuth Thruster
#n (unavailable)
Bow Thruster #n (invalid) There is a format error or
Bow Thruster #n (not
plausible)
Bow Thruster #n
(unavailable)
CCU Fan
CIF(Communication
error)
CMP
RelaySoftware(Commun
ication error)
COG/SOG(invalid)
COG/SOG(not plausible) There is a range error of
COG/SOG(unavailable)
CPU Core1 Clock down
CPU Core1 High TEMP
CPU Core2 Clock down
CPU Core2 High TEMP
CPU Fan
CPU High TEMP
Appendix A Alert, Maintenance INFO and Permanent information
Explanation
There is a range error of
the data.
The data cannot be
received.
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
The CCU unit fan
revolution per minute has
been decreased.
There is an error in
communication with
Companion MPU.
There is an error in
communication with
Companion MPU.
There is a format error or
a status error of the
SOG/COG data.
SOG/COG data.
The SOG/COG data
cannot be received.
The CPU core has been
underclocked.
The CPU core
temperature is too high.
The CPU core has been
underclocked.
The CPU core
temperature is too high.
The RPS fan revolution
per minute has been
decreased.
The CPU temperature is
too high.
Advice
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Request the distributor to repair.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
Request the distributor to repair.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
A-24

Advertisement

loading

This manual is also suitable for:

Jan-9201s