22.5 Power Supply Unit
GENERAL SPECIFICATION
AC Input
Voltage
Voltage Range
Overvoltage Protection
Input Current
Over current Protection
DC Input
Voltage
Voltage Range
Overvoltage Protection
Input Current
Over current Protection
Rated Output
Output 1
Output 2A (for CCU)
Output 2B (for MNU)
Output 3 (for TXRX)
Mechanical
Dimension
Mass
FAN
Environment
Operational Temperature
Operational Humidity
Vibration
EMC
Ingress Protection Rating
NBD-913: Power Supply Unit
100 to 115VAC, 50/60Hz 1
220 to 240VAC, 50/60Hz 1
85 to 264VAC
295VAC±2V
Max 6.8A(100VAC) / 3.4A(220VAC)
YES
24VDC
21.6 to 31.2VDC
42V
Max 16A
YES
12.0V±0.24V 2A
24.0V±0.48V 4A
24.0V±0.48V 6A
48.0V±0.96V 4A
Width 400 x Depth 240 x Height 85 (mm)
4.2kg
2
-15C to +55C
40C RH 93%
Sweep 2 Hz to 13.2 Hz at ± 1 mm, 13.2 Hz to 100 Hz at
7m/s2 and for 2h on each resonance, otherwise 2h at
30Hz in all three axes
IEC60945-Ed4.0
IP20