Probe Replacement - Henny Penny Evolution Elite EEG-142 Technical Manual

Reduced oil capacity open fryers (split vat & full vat– gas)
Hide thumbs Also See for Evolution Elite EEG-142:
Table of Contents

Advertisement

6-7. PROBE REPLACEMENT

Oil
Temperature
level
probe
probe
Nov. 2009
The temperature probe is the center probe inside the vat (see
photo at left) and it relays the actual oil temperature to the con-
trol. If it becomes disabled, "E-6A or B" shows in the display.
The oil level probes (left & right-see photo at left) monitor the
oil level by temperature differences. If they becomes disabled,
the display shows: "E-18A"= left probe; "E18-B"= right probe;
"E18C"= both.
Also, if any of the probes are out of calibration more than 5°F,
or 5°C, the probe should be replaced. An Ohm check can be
performed also. See chart below.
Checkout:
Oil
To avoid electrical shock or property damage, move the
level
power switch to OFF and disconnect main circuit
probe
breaker, or unplug cord at wall receptacle.
1. Using a Phillip's-head screwdriver, or cordless drill, loosen
the screw securing the top of the control panel and secure
control panel in the slots of the shroud.
2. Pull the probe connector from the control panel and locate the
terminals in the connector for the probe being tested. Attach
meter leads onto those terminals and refer to the chart at left
to determine if probe is good or not. (Probe wires are labeled,
with #1 being the far left probe.)
6-6
Model EEG-142, 143, 144

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution elite eeg-143Evolution elite eeg-144

Table of Contents