6-13. TRANSFORMERS
AIF Transformer
Control Transformer Connector
Control Transformer
AIF Transformer
Nov. 2009
These components drop the line voltage to low voltage com-
poents such as, control board, AIF board and gas valves.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Pull-down the control panel to access the desired trans-
former.
2. Label and remove wires from (AIF) transformer, or discon-
nect the white connector on the control transformer.
3. Using a 5/16" socket, remove the nuts securing the trans-
former and pull the transformer from unit.
4. Replace transformer in reverse order.
6-15
Model EEG-142, 143, 144