6-11. JIB PUMP

6-12. EXPRESS FILTER PC
BOARD
Nov. 2009
This pump keeps the vats filled and is used in the Automatic
Intermittant Filter process.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
1. Remove the right side panel.
2. Using a 1" wrench, loosen both fitting on each side of the
pump.
3. Using a Phillip's-head screwdriver, remove the 4 screws
securing the bottom of pump.
4. Disconnect the wires in the rear of the pump and pull as-
sembly from fryer.
5. Pull fittings from faulty pump and attach the fittings to the
new pump, in the same orientation.
6. Install new pump assembly in fryer, in reverse order and
then reconnect power to fryer.
This electronic board controls the Automatic Intermittant Fil-
tering process.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the left side panel.
2. Using a 3/8" socket or nut driver, remove the nuts securing
the cover and remove cover.
3. Pull connectors from PC board.
4. Using a 5/16" socket, remove the 6 nuts securing the board
and remove it from the fryer.
5. Install in reverse order. The control connectors are colored-
coded; Left-Red; Middle-White; Right-Blue.
6-14