Mounting

Mounting Method

Mounting methods include use of Top/Bottom Brackets, Top/Bottom Brackets + Intermediate Brackets,
Intermediate Brackets only (Free-Location Mounting) and use of One-touch Brackets. Any of these
mounting methods allows the user to use the same bracket for the backside mounting and side
mounting.

Number of Brackets Required

The numbers of brackets required according to the protective heights of the sensor are as follows:
•When Using Top/Bottom Brackets Only --> p.72
•When Using Top/Bottom + Intermediate Brackets --> p.74
Protective height
0185 to 1105
1185 to 1345
1425 to 2065
• When Using Intermediate Brackets Only --> p.78
Protective height
0185 to 0225
0305 to 1105
1185 to 1585
1665 to 2065
• When Using One-touch Bracket --> p.81
Protective height
0185 to 1105
1185 to 1585
1665 to 2065
Number of Top/
Number of
Bottom Brackets
Intermediate Brackets
2
2
2
Number of
Intermediate Brackets
1
2
3
4
Number of One-touch
Brackets
2
3
4
0
1
2
Wiring/Installation
F3SJ-E/B
User's Manual
E
71