Connecting A F3Sj-B To Various Controllers - Omron Sti F3SJ-E N25 Series User Manual

Table of Contents

Advertisement

Input/Output Circuit and Applications

Connecting a F3SJ-B to Various Controllers

 Connecting a F3SJ-B to a G9SA-301-P
F39-JD A-L
+24 VDC
Power
Supply
0 V
A1
Model G9SA-301-P
F3SJ-E/B
102
User's Manual
Communication
line (+) (Grey)
Communication
line (-) (Pink)
Feedback loop
A2
T11
T12
T31
T32
6
K1
K2
a
K1
K2
Control
a
K1
b
Circuit
b
K2
1
PE
T21
T23
T22
A
B
Unblocked
Blocked
External test switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1
PLC input 2
PLC output
- F3SJ-B settings
- Auto reset mode
- Does not use external device monitoring function
- G9SA-301-P settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
F39-JD A-D
PLC
IN1
*1
12
22
11
21
S3
KM1
KM2
13
23
33
41
3
4
1
2
3
4
2
JP
5
5
6
42
14
24
34
0 V
KM1
KM2
IN2
OUT
KM3
KM1
KM2
M
*1 If an emergency stop switch is not used, connect safety
output 1 to T12 terminal and safety output 2 to T23 directly.
S1
: External test switch
(connect to 24 V if a switch is not required)
S2
: Interlock reset switch
S3
: Emergency stop switch (force-opening contact)
(A165E, A22E)
S4
: Lockout reset switch
(connect to 0 V if a switch is not required)
KM1, KM2 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
KM3
: Solid state contactor (G3J)
M
: 3-phase motor
PLC
: Programmable controller
(Used for monitoring -- not related to safety system)