Wiring/Installation
 Side mounting
Top/Bottom Bracket
(F39-LJB1)
Intermediate Bracket
(F39-LJB2)
Top/Bottom Bracket
(F39-LJB1)
Dimensions A to E
A
B
C
D
E
Dimensions E
Protective height
0185 to 1105
1185 to 1345
1425 to 2065
* Value E must be 700 mm or less when not using value E obtained from the calculation above.
Bracket mounting procedure (Mounting) p.71
- If the protective height is more than 1105 mm, use Intermediate Brackets of specified quantities and locations
according to the dimensions. If the brackets described above are not used, ratings and performance cannot be met.
- When you use a sensor in a situation where the sensor is under a load, add an Intermediate Bracket.
F3SJ-E/B
52
User's Manual
30
19
dia.9
6.5
M3 x 6 screw
30
7
34
42
12
45
C+69
C+42.2
4-digit number of the type name (protective height)
C-45
Depends on the protective height. See the table below.
Number of Intermediate Brackets
0
1
2
46
30
4-M5
22
2-M5
16
M3 x 6 screw
<M5 screw fixed>
Dimensions E
-
C/2 max.
C/3 max.
19
2-M8
22
2-M5
<M8 screw fixed>
[ Unit : mm ]