Wiring Method (Easy Type); Wiring Method (Basic Type) - Omron Sti F3SJ-E N25 Series User Manual

Table of Contents

Advertisement

Wiring/Installation

Wiring Method (Easy Type)

Directly wire the single-ended cable that is routed from the sensor.
<F3SJ cable> (The figure shown below is the cable for the emitter.)
To extend the cable, the following specifications must be satisfied.
<Extension cable>
Refer to "<Extension cable>" on page 91.

Wiring Method (Basic Type)

Perform wiring according to the following procedure.
1.
Connect an emitter cable (F39-JD-L, gray, sold separately) to the emitter's connection cable (gray).
2.
Connect a receiver cable (F39-JD-D, black, sold separately) to the receiver's connection cable
(black).
3.
Connect the +24 V line of the power supply directly to the protective earth (PE).
 Single-ended connector cable (F39-JDA, sold separately)
Set model
name
F39-JD3A
F39-JD7A
F39-JD10A
F39-JD15A
F39-JD20A
F3SJ-E/B
88
User's Manual
Insulated vinyl round cord dia. 6
Emitter: 5-wire, Receiver: 6-wire (Cross section of conductor: 0.15mm
39.5
Insulated vinyl round cable dia. 6.6, shielded 8-wire (4-pair)
(Cross section of conductor: 0.3mm
M12 IP67 connector
Emitter cable
F39-JD3A-L
Gray cable
F39-JD7A-L
F39-JD10A-L
F39-JD15A-L
F39-JD20A-L
2
L
2
/insulator diameter: dia. 1.15mm)
Receiver cable
F39-JD3A-D
Black cable
F39-JD7A-D
F39-JD10A-D
F39-JD15A-D
F39-JD20A-D
/ Insulator diameter: 1mm)
(Unit: mm)
L (mm)
3000
7000
10000
15000
20000

Advertisement