Omron Sti F3SJ-E N25 Series User Manual page 49

Table of Contents

Advertisement

To enable the muting function, D3 and d2 must satisfy formulas (3) and (4), respectively.
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ-B and muting sensors so that each workpiece passes through
all muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
Moving direction
<Wiring diagram>
Using a photoelectric switch as a muting sensor
B1
A1
F3SJ-B
* Two-wire type muting sensor cannot be used.
Workpiece
B2
A1, B1, A2, B2 :
Retro-reflective
photoelectric switch
- NPN Output
- ON when Interrupted
A2
System Configuration and Functions
Workpiece
Workpiece
Moving direction
Using an N.O. contact type switch as a muting sensor
A1
A2
B1
B2
A1, A2, B1, B2:
N.O. contact type switch
+24 VDC
Power
supply
0 V
F3SJ-E/B
User's Manual
E
33

Advertisement

Table of Contents
loading

Table of Contents