Omron Sti F3SJ-E N25 Series User Manual page 53

Table of Contents

Advertisement

 Override end conditions
When either of the following conditions is satisfied, the function is released.
•When 60 seconds has elapsed under the override status
•All muting sensors are turned OFF
•When the reset input is turns from OFF to ON and/or the test input turns from ON to OFF
Override state can be also released when the sensor enters lockout.
<Timing chart>
ON
Muting input 1
OFF
ON
Muting input 2
OFF
ON
Reset input
OFF
ON
Test input
OFF
Enabled
Override state
Disabled
blinking
Auxiliary output
OFF
Unblocked
Unblocked
Blocked
/Blocked
ON
Safety output
OFF
T1
0.1 s max.
T1 : Override Input Time Limit : 0.3 s
T2 : Override Time Limit : 60 s
System Configuration and Functions
T2 max.
1 Hz Blinking
E
F3SJ-E/B
37
User's Manual