Omron Sti F3SJ-E N25 Series User Manual page 107

Table of Contents

Advertisement

 Simple wiring connector (optional: F39-CN5)
(52)
13.6
24.7
13.6 φ 8 (SPOT FACING 2)
12
φ 4.5
10
32.1
17.7
18
Internal Wiring Diagram (Optional: F39-CN5)
Connected to emitter's connection cable
and Cable with connectors on both ends
1
White
2
Brown
3
Black
1
2
4
Yellow
7
3
8
6
4
5
Grey
5
6
Pink
Female
7
Blue
8
Red
When you need to use a cable that is not specified by OMRON, use a cable that satisfies the following
specifications.
<Extension cable>
Easy Type
1. Emitter
: 5-wire (0.12 mm
ohms/m max.)
Receiver : 6-wire (0.12 mm
2. Emitter
: Communication lines (+) and (-) must be used as twisted-pair lines.
Receiver : Communication lines (+) and (-), safety output lines 1 and 2 must be used as twisted-pair
lines.
Basic Type
1. 8-wire (0.3 mm
or larger x 4 pairs, conductor resistance 0.058 ohms/m max.)
2
2. Braided shield
3. Connect the pin No. 7 with the shield line.
4. Communication lines (+) and (-), 24 V and 0 V lines must be used as twisted-pair lines.
Do not use cables in the same conduit as high voltage or electric power lines.
1
2
3
4
5
2
1
3
7
8
6
4
5
Male
or larger x 1 pair, 0.12 mm
2
2
or larger x 3 pairs, conductor resistance 0.146 ohms/m max.)
Wiring/Installation
Connected to receiver's connection cable
and Cable with connectors on both ends
White
1
Brown
2
Black
3
Yellow
4
Grey
5
Pink
6
Blue
7
Red
8
6
7
8
or larger x 3, conductor resistance 0.146
2
1
2
7
3
8
6
4
5
Female
E
F3SJ-E/B
91
User's Manual

Advertisement

Table of Contents
loading