Using F3SJ-B Only

 Basic system
F39-JD A-L
+24 VDC
Power
Supply
0 V
Unblocked
Blocked
External test switch (S1)
Reset switch (S2)
Safety output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
PLC input *
PLC output
F39-JD A-D
Communication
line (+) (Gray)
Communication
line (-) (Pink)
KM1
KM2
IN
PLC
* Auxiliary output gives inverted signal of safety output.
Input/Output Circuit and Applications
- Manual reset mode
- Using external device monitoring function
KM1
KM2
M
OUT
S1
:External test switch (connect to 24 V if a switch is not required)
S2
:Interlock/lockout reset switch
KM1, KM2 :Safety relay with force-guided contact (G7SA)
or magnetic contactor
KM3
:Solid state contactor (G3J)
M
:3-phase motor
PLC
:Programmable controller
(Used for monitoring -- not related to safety system)
KM3
KM1
KM2
F3SJ-E/B
97