Omron Sti F3SJ-E N25 Series User Manual page 94

Table of Contents

Advertisement

Wiring/Installation
 When using Intermediate Bracket (Free-Location Mounting)
1.
Loosen the hexagon socket head cap screw (M3 x 18) of the intermediate bracket (3) and the hexagon
socket head cap screw (M3 x 12) of the intermediate bracket (1) to be able to attach the bracket to the
sensor case. (Figure 15 and 16)
The intermediate bracket has been assembled for backside mounting.
To use it for side mounting, remove the intermediate bracket (2) from the intermediate bracket (3) and
change the direction of the bracket as shown in Fig.16.
Backside mounting
Hexagon socket head
cap screw (M3 x 18)
Side mounting
Detach the intermediate
mounting bracket (2) from (3).
Hexagon socket head
cap screw (M3 x 12)
Loosen
Hexagon socket head
cap screw (M3 x 18)
2.
Mount the Intermediate Bracket to the case, and lightly tighten the hexagon socket head cap screws
(M3 x 12) of Intermediate Bracket (1). (Figure 17)
Intermediate Bracket (1)
Tighten lightly
F3SJ-E/B
78
User's Manual
Hexagon socket head
cap screw (M3 x 12)
Loosen
Intermediate Bracket (1)
Loosen
Intermediate Bracket (3)
Figure 15
Intermediate
Bracket (2)
Intermediate Bracket (1)
Intermediate Bracket (2)
Intermediate Bracket (3)
Backside mounting
Optical surface
Intermediate
Bracket (2)
Sensor is secured by
Intermediate Brackets.
Intermediate Bracket (2)
Turn the intermediate mounting bracket (2) so that
the intermediate bracket (1) should be the bottom.
Intermediate Bracket (1)
Intermediate Bracket (2)
Intermediate Bracket (3)
Figure 16
Optical surface
Intermediate
Bracket (3)
Intermediate Bracket (2)
Figure 17
Attach the intermediate
mounting bracket (2) to (3).
Intermediate
Bracket (1)
Intermediate Bracket (3)
Side mounting
Intermediate Bracket (1)
Tighten lightly
Intermediate
Bracket (3)
Sensor is secured by
Intermediate Brackets.
Loosen

Advertisement

Table of Contents
loading