Phoenix Contact FL SWITCH 2000 Series Installation And Startup Manual

Phoenix Contact FL SWITCH 2000 Series Installation And Startup Manual

Table of Contents

Advertisement

Installation and startup of the
FL SWITCH 2000 and FL NAT 2000 product
families
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FL SWITCH 2000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix Contact FL SWITCH 2000 Series

  • Page 1 Installation and startup of the FL SWITCH 2000 and FL NAT 2000 product families User manual...
  • Page 2 FL SWITCH 2212-2TC-2SFX 2702907 FL SWITCH 2514-2SFP 1043499 FL SWITCH 2308 2702652 FL SWITCH 2514-2SFP PN 1089154 FL SWITCH 2308 PN 1009220 FL SWITCH 2512-2GC-2SFP 1088856 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
  • Page 3: Table Of Contents

    Installing the devices ................29 FL SWITCH 24xx/25xx ..................30 3.4.1 Device dimensions ................30 3.4.2 Elements of the devices ............... 31 3.4.3 Mounting and removing the devices ............ 31 3.4.4 Installing the devices ................33 3 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 4 FL SWITCH 2208C....................73 5.11 FL SWITCH 2208 PN ..................75 5.12 FL SWITCH 2207-FX ..................78 5.13 FL SWITCH 2207-FX SM ..................81 5.14 FL SWITCH 2206-2FX ..................83 5.15 FL SWITCH 2206C-2FX ..................86 4 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 5 FL SWITCH 2414-2SFX PN ................170 5.48 FL SWITCH 2412-2TC-2SFX ................172 5.49 FL SWITCH 2508 ....................175 5.50 FL SWITCH 2508/K1..................177 5.51 FL SWITCH 2508 PN ..................179 5.52 FL SWITCH 2506-2SFP ..................182 5 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 6 FL SWITCH 2708 PN ..................210 5.65 FL NAT 2008 ..................... 212 5.66 FL NAT 2208 ..................... 214 5.67 FL NAT 2304-2GC-2SFP................... 216 Appendix for document lists....................221 List of figures ..................... 221 List of tables ...................... 223 6 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 7: For Your Safety

    Modifications to hardware and firmware of the device are not permitted. Incorrect operation or modifications to the device can endanger your safety or damage the device. Do not repair the device yourself. If the device is defective, please contact Phoenix Contact. 7 / 226 PHOENIX CONTACT...
  • Page 8: Unauthorized Network Access

    §§15ff. AktG (German Stock Corporation Act), hereinafter collectively referred to as “Phoenix Contact”, from all third-party claims made due to improper use. For the protection of networks for remote maintenance via VPN, Phoenix Contact offers the mGuard product series security appliances, which you can find described in the latest Phoenix Contact catalog (phoenixcontact.net/products).
  • Page 9: Properties Of The Devices

    2 x MM SC FL SWITCH 2214-2FX SM 14 x RJ45 2 x SM SC FL SWITCH 2214-2SFX 14 x RJ45 2 x SFP FL SWITCH 2214-2SFX PN PROFINET mode 14 x RJ45 2 x SFP 9 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 10 PROFINET mode 6 x RJ45 2 x SFP FL SWITCH 2504-2GC-2SFP 4 x RJ45 2 x combo, 2 x SFP FL SWITCH 2516 16 x RJ45 FL SWITCH 2516 PN PROFINET mode 16 x RJ45 10 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 11: Fl Nat 2Xxx Device Versions

    TX ports (M12), 10/100/1000 Mbps (versions 27xx) Fiberglass ports: – FO ports (ST duplex, SC duplex), 100 Mbps (versions 22xx) – SFP ports (SFX), 100 Mbps (versions 22xx, 24xx) – SFP ports (SFP), 100/1000 Mbps (versions 23xx, 25xx) 11 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 12: Overview Table Of The Functions

    No/yes Yes (optional)/Yes Fast Ring Detection (FRD) Large Tree Support Link Aggregation (LACP) Management functions Role-based user management Port configuration Address Conflict Detection (ACD) DHCP server Port-based Pool/port-based, option 82 Command Line Interface (CLI) 12 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 13 Security MAC-based port security RADIUS authentication (IEEE 802.1X) Layer 3 functions (FL NAT versions only) Static routing 1:1 NAT Port forwarding (1:n NAT) Virtual NAT No FL NAT versions are available for these series. 13 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 14: Status And Diagnostic Indicators

    The LNK/ACT LED is located directly at the top of the port. The SPD LED is always located at the bottom of the port. 24xx/25xx versions: The LEDs are located on the front of the device. 14 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 15: Description Of The Integrated Fiberglass Transceivers

    Properties of the devices Description of the integrated fiberglass transceivers Some versions of the FL SWITCH 2000 series have integrated fiberglass transceivers with an SC duplex or ST duplex pin connector pattern. When the device has been mounted in accordance with the instructions (see...
  • Page 16: Using The Sfp Slots (Principle)

    Figure 23 Inserting the SFP modules (example) Removing the SFP modules • Remove the FO connector before removing the SFP module. • Turn the release latch to the side and pull out the SFP module. 16 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 17: Using The (Micro)Sd Card

    Please note that correct function of the SD card and the product can only be ensured when using a Phoenix Contact SD card (e.g., 2988162 SD FLASH 2GB or 1129482 FL MICRO SD FLASH). If third-party SD cards are used, it is recommended that card compatibility be verified.
  • Page 18 During reading on a 5/8-port device, the entries for configuration of ports 9 to 16 are ignored. Inversely, the parameters of ports 9 to 16 are set to the factory default when the config- uration of a 5/8-port device is read on a 16-port device. 18 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 19: Mounting And Installation

    1000Base-T (1000 Mbps) TD+ (transmit) TD+ (transmit) BI_DA+ (bidirectional) TD- (transmit) TD- (transmit) BI_DA- (bidirectional) RD+ (receive) RD+ (receive) BI_DB+ (bidirectional) BI_DC+ (bidirectional) BI_DC- (bidirectional) RD- (receive) RD- (receive) BI_DB- (bidirectional) BI_DD+ (bidirectional) BI_DD- (bidirectional) 19 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 20: Pin Assignment Of D-Coded M12 Connectors

    3.1.2.2 D-coded M12 Ethernet connectors You can use M12 connectors with standard screw connection or M12 push-pull connectors from Phoenix Contact. Only devices in the 26xx version feature Ethernet ports in D-coding. Table 3-2 Pin assignment of D-coded M12 connectors...
  • Page 21: Fl Switch 20Xx/21Xx/22Xx/23Xx And Fl Nat 2Xxx

    Mounting and installation FL SWITCH 20xx/21xx/22xx/23xx and FL NAT 2xxx 3.2.1 Device dimensions Figure 31 Dimensions of 5/8-port versions in a narrow housing Figure 32 Dimensions of 16-port versions in a narrow housing 21 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 22: Elements Of The Devices

    Mount the device on a clean, horizontally installed DIN rail in accordance with DIN EN 50022 (e.g., NS 35 ... from Phoenix Contact). To avoid contact resistance, only use clean, corrosion-free DIN rails. End brackets (E/NS 35 N, Order No. 0800886) can be mounted to the right and left of the device to stop the modules from slipping on the DIN rail.
  • Page 23: Snapping The Device Onto The Din Rail

    On the 16-port devices, the positive latch remains snapped out. Then slightly swivel the bottom of the device away from the DIN rail (C). Lift the device upwards away from the DIN rail (D). Figure 35 Removing the device 23 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 24: Installing The Devices

    DIN 46228) DIN 46228) Suitable screwdriver Slot-headed screwdriver Blade thickness: 0.4 mm Blade width: 2.5 mm Recommended: SZS 0,4X2,5 VDE, Order No. 1205037 Conductor cross-section, AWG, minimum Conductor cross-section, AWG, maximum Stripping length 9 mm 24 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 25: Operating The Device With One Power Supply (Example)

    1 2 3 4 5 Figure 37 Redundant operation with two power supplies (example) Please note that load distribution does not take place. The power supply unit with the higher voltage will supply the device on its own. 25 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 26: Connecting A Relay To The Digital Alarm Output

    1 2 3 4 5 Figure 38 Connecting a relay to the digital alarm output Please note that the relay must be suitable for the operating voltage. Use the RIF-0-RPT-24DC/21 (Order No. 2903370), for example. 26 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 27: Fl Switch 20Xxf

    Elements of the FL SWITCH 20xxF devices Table 3-7 Key for FL SWITCH 20xxF Number Meaning Connection of the supply voltage RJ45 ports Smart mode button Diagnostic and status indicators Slot for optional microSD card 27 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 28: Mounting And Removing The Devices

    Mount the device on a clean, horizontally installed DIN rail in accordance with DIN EN 50022 (e.g., NS 35 ... from Phoenix Contact). To avoid contact resistance, only use clean, corrosion-free DIN rails. End brackets (E/NS 35 N, Order No. 0800886) can be mounted to the right and left of the device to stop the modules from slipping on the DIN rail.
  • Page 29: Installing The Devices

    DIN 46228-1 Cross-section: 0.5 mm Length: 8 mm … 10 mm Cross-section: 0.75 mm Length: 8 mm … 10 mm Cross-section: 1 mm Length: 8 mm … 10 mm Cross-section: 1.5 mm Length: 10 mm 29 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 30: Fl Switch 24Xx/25Xx

    The module is designed exclusively for operation with safety extra-low voltage (SELV/PELV). Figure 313 Power supply of the switch FL SWITCH 24xx/25xx 3.4.1 Device dimensions Figure 314 Dimensions of 8-port versions Figure 315 Dimensions of 16-port versions 30 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 31: Elements Of The Devices

    Mount the device on a clean, horizontally installed DIN rail in accordance with DIN EN 50022 (e.g., NS 35 ... from Phoenix Contact). To avoid contact resistance, only use clean, corrosion-free DIN rails. End brackets (E/NS 35 N, Order No. 0800886) can be mounted to the right and left of the device to stop the modules from slipping on the DIN rail.
  • Page 32: Removing The Device

    Then slightly swivel the bottom of the device away from the DIN rail (B1). Lift the device upwards away from the DIN rail (B2). Figure 318 Removing the device 32 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 33: Installing The Devices

    Conductor cross-section, flexible, with ferrule with plastic sleeve, minimum 0.25 mm Conductor cross-section, flexible, with ferrule with plastic sleeve, maximum 1.5 mm Conductor cross-section, AWG, minimum Conductor cross-section, AWG, maximum Stripping length 10 mm 33 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 34: Supplying The Switch Using One Voltage Source

    Redundant 24 V DC supply 24 V DC Figure 320 Supplying the switch using two voltage sources In order to reset the switch on power up, the power supply must be interrupted for at least three seconds. 34 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 35 This error message can be prevented by connecting the supply voltage to both US1/US2 terminal blocks in parallel (as shown in Figure 319) or by deactivating redundant power supply monitoring in web-based management or via SNMP. 35 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 36: Fl Switch 26Xx/27Xx

    FL SWITCH 2000 / FL NAT 2000 FL SWITCH 26xx/27xx 3.5.1 Device dimensions Figure 322 Dimensions of the FL SWITCH 26xx/27xx devices 3.5.2 Elements of the devices Figure 323 Elements of the FL SWITCH 26xx/27xx devices 36 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 37: Mounting And Removing The Devices

    For mounting, use M5 or M6 screws with a head diameter larger than 7 mm and up to 10.3 mm, maximum. When using M4 screws, you have to use washers. The use of Schnorr safety washers in accordance with DIN 6798 is possible. Observe the maximum torque of the screws. 37 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 38: Installing The Devices

    3.5.4.2 Connecting the 24 V DC supply voltage You can use M12 connectors with standard screw connection or M12 push-pull connectors from Phoenix Contact. • Use the XD1 socket for the power supply of the device. For the standard 26xx/27xx versions, power is supplied via an A-coded M12 connector.
  • Page 39 Ensure fuse protection for the power supply that is suitable for your design. If the permissible current carrying capacity is exceeded, this may result in damage to the connectors, the electronic components, and to the PCB of the device. We recommend using pre-assembled cables. 39 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 40 FL SWITCH 2000 / FL NAT 2000 40 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 41: Startup And Function

    IP address. To avoid IP address conflicts when starting multiple devices simultaneously, conflict detection is also active. If the switch detects that the adopted IP address is already assigned, it chooses another one at random. 41 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 42: Configuration In The Delivery State

    – The MAC address table does not contain any entries. – LLDP is activated. – SNTP is deactivated. – 802.1x and port-based security are deactivated. – The “Universal” Quality of Service profile is activated. 42 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 43: Using Smart Mode

    When Smart mode is started, the switch is initially in the “Exit without changes” state. 4.2.2 Selecting the desired setting • To select the various settings, press the Smart mode button briefly and select the de- sired operating mode (see Table “Operating modes in Smart mode”). 43 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 44: Possible Operating Modes In Smart Mode

    42. This deletes any configurations stored on the device. An automation pro- tocol is not activated in this mode. The initial IP configuration is activated (see Section “Initial IP configuration in the delivery state” on page 41). 44 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 45: Operation In Profinet Mode

    0.0.0.0 and BootP is activated. Any other configurations stored on the device are retained and are not deleted. The initial IP configuration is activated (see Section “Initial IP configuration in the delivery state” on page 41). 45 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 46: Operation In Unmanaged Mode

    Internet. You can use any of these programs for address assignment. This section explains IP address assignment using the “FL NETWORK MANAGER BASIC” (Order No. 2702889) and the “IP Assignment Tool” software tools from Phoenix Contact. Notes on BootP During initial startup, the device sends BootP requests without interruption until it receives a valid IP address.
  • Page 47: Assigning The Ip Address Using Fl Network Manager Basic

    In your project in the BOOTP/DHCP SERVER window, click on the “play” icon next to the selected network interface. The BootP server is now activated. • BootP requests that are received are listed in the BOOTP/DHCP SERVER window in table format. 47 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 48: Figure 42 Bootp Server

    You can check whether IP address assignment was successful in the “IP address” column in the BOOTP/DHCP SERVER window. Figure 43 FL NETWORK MANAGER with BootP/DHCP reservation list shown The IP parameters set here can be changed in web-based management, if required. 48 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 49: Assigning The Ip Address Using Ipassign.exe

    The MAC address of your switch can be found on the sticker on the side. In this example, the switch has MAC address 00.A0.45.04.08.A3. • Select the device to which you want to assign an IP address. • Click on the “Weiter” (Next) button. 49 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 50: Figure 45 "Set Ip Address" Window With Incorrect Settings

    Click on the “Weiter” (Next) button. Step 5: “Assign IP Address” The program attempts to transfer the set IP parameters to the device. Figure 46 “Assign IP Address” window Following successful transfer, the next window opens. 50 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 51 • Click on the “Zurück” (Back) button. To exit the IP address assignment: • Click on the “Fertig stellen” (Finish) button. The IP parameters set here can be changed in web-based management, if required. 51 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 52 FL SWITCH 2000 / FL NAT 2000 52 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 53: Technical Data

    246.55 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 56.66 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 53 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 54 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 54 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 55: Fl Switch 2008

    General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 220 g 55 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 56 Maximum power dissipation for nominal condition 4.86 W (At U = 18 V DC and 60°C ambient temperature) Test section for one minute 500 V DC Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 56 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 57: Fl Switch 2008F

    Degree of protection IP30 Protection class III (VDE 0106) Degree of pollution Ambient temperature (operation) 0 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) 57 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 58 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 58 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 59: Fl Switch 2016

    Ambient temperature (operation) 0 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 59 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 60 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 60 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 61: Fl Switch 2105

    UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1 UL, Canada CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010- 1-12, Ed.3 Further approvals cULus Listed, EAC FL SWITCH 2105 Ordering data Order designation FL SWITCH 2105 Order No. 2702665 Pcs./Pkt. 61 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 62 (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.25 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² 62 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 63 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1 UL, Canada CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010- 1-12, Ed.3 Further approvals cULus Listed, EAC, CC-Link IE Field 63 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 64: Fl Switch 2108

    174.97 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 31.76 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 64 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 65 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 65 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 66: Fl Switch 2116

    General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 435 g 66 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 67 Maximum power dissipation for nominal condition 12.6 W (At U = 18 V DC and 60°C ambient temperature) Test section for one minute 500 V DC Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 67 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 68: Fl Switch 2205

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 68 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 69 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 69 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 70 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 70 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 71: Fl Switch 2208

    235.18 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 29.73 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 71 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 72 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 72 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 73: Fl Switch 2208C

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 73 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 74 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 74 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 75: Fl Switch 2208 Pn

    EN 61000-6-2 EN 61000-4-5 (surge) Criterion B Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 5.11 FL SWITCH 2208 PN Ordering data Order designation FL SWITCH 2208 PN Order No. 1044024 Pcs./Pkt. 75 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 76 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 76 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 77 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 77 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 78: Fl Switch 2207-Fx

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 78 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 79 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 79 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 80 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc  IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 80 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 81: Fl Switch 2207-Fx Sm

    Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 240 g Housing material Polycarbonate fiber reinforced MAC address table 81 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 82 100 Mbps (full duplex) Transmission length 36000 m (fiberglass with F-G 9/125 0.36 dB/km) Transmission length 32000 m (fiberglass with F-G 9/125 0.4 dB/km) Transmission length 26000 m (fiberglass with F-G 9/125 0.5 dB/km) Wavelength 1300 nm 82 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 83: Fl Switch 2206-2Fx

    Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 5.14 FL SWITCH 2206-2FX Ordering data Order designation FL SWITCH 2206-2FX Order No. 2702330 Pcs./Pkt. 83 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 84 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 9 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 84 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 85 1.5 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 6.75 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 85 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 86: Fl Switch 2206C-2Fx

    FL SWITCH 2206C-2FX Order No. 1095628 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 45 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 Protection class III, VDE 0106 Degree of pollution 86 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 87 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 87 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 88 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU 88 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 89: Fl Switch 2206-2Fx Sm

    153.37 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 18.66 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 89 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 90 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 235 mA (at U = 24 V DC and 25 °C ambient temperature) 90 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 91: Fl Switch 2206-2Fx St

    Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 5.17 FL SWITCH 2206-2FX ST Ordering data Order designation FL SWITCH 2206-2FX ST Order No. 2702332 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 45 mm Height 130 mm Depth 115 mm 91 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 92 Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.25 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² 92 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 93 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 93 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 94: Fl Switch 2206-2Fx Sm St

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 94 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 95 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 95 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 96 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 96 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 97: Fl Switch 2206-2Sfx

    General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 290 g 97 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 98 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (Depending on the fiber/SFP module used) 98 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 99: Fl Switch 2206-2Sfx Pn

    Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 5.20 FL SWITCH 2206-2SFX PN Ordering data Order designation FL SWITCH 2206-2SFX PN Order No. 1044028 Pcs./Pkt. 99 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 100 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 100 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 101 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 101 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 102: Fl Switch 2204-2Tc-2Sfx

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 102 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 103 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 103 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 104 Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A 104 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 105: Fl Switch 2216

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 105 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 106 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 106 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 107: Fl Switch 2216 Pn

    Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 5.23 FL SWITCH 2216 PN Ordering data Order designation FL SWITCH 2216 PN Order No. 1044029 Pcs./Pkt. 107 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 108 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 108 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 109 EN 61000-6-2 EN 61000-6-3 (conducted emissions) Class B Interference emission EN 61000-6-2 EN 61000-6-3 (noise emission) Class B Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 109 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 110: Fl Switch 2214-2Fx

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 110 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 111 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 111 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 112 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc  IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 112 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 113: Fl Switch 2214-2Fx Sm

    Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 470 g Housing material Polycarbonate fiber reinforced MAC address table 113 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 114 100 Mbps (full duplex) Transmission length 36000 m (fiberglass with F-G 9/125 0.36 dB/km) Transmission length 32000 m (fiberglass with F-G 9/125 0.4 dB/km) Transmission length 26000 m (fiberglass with F-G 9/125 0.5 dB/km) Wavelength 1300 nm 114 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 115: Fl Switch 2214-2Sfx

    Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 5.26 FL SWITCH 2214-2SFX Ordering data Order designation FL SWITCH 2214-2SFX Order No. 1006188 Pcs./Pkt. 115 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 116 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 116 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 117 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 117 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 118: Fl Switch 2214-2Sfx Pn

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 118 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 119 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 119 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 120 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc  IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 120 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 121: Fl Switch 2212-2Tc-2Sfx

    Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 480 g Housing material Polycarbonate fiber reinforced MAC address table 121 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 122 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (Depending on the fiber/SFP module used) 122 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 123 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 123 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 124: Fl Switch 2308

    165.29 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 20.35 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 124 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 125 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 125 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 126: Fl Switch 2308 Pn

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 126 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 127 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 127 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 128 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA, PROFINET 128 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 129: Fl Switch 2306-2Sfp

    212.99 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 24.97 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 129 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 130 1.5 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 9 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 130 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 131: Fl Switch 2306-2Sfp Pn

    FL SWITCH 2306-2SFP PN Order No. 1009222 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 45 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 Protection class III, VDE 0106 Degree of pollution 131 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 132 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 132 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 133 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion B Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 133 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 134: Fl Switch 2304-2Gc-2Sfp

    General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 310 g 134 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 135 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100/1000 Mbps (full duplex) Transmission length up to 80 km (depending on the SFP module used) 135 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 136 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 136 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 137: Fl Switch 2316

    199.41 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 27.52 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 137 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 138 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 138 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 139: Fl Switch 2316 Pn

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 139 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 140 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 140 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 141 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA, PROFINET 141 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 142: Fl Switch 2314-2Sfp

    199.41 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 27.52 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 142 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 143 2 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 15.6 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 143 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 144: Fl Switch 2314-2Sfp Pn

    FL SWITCH 2314-2SFP PN Order No. 1031683 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 85 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 Protection class III, VDE 0106 Degree of pollution 144 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 145 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 145 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 146 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 146 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 147: Fl Switch 2312-2Gc-2Sfp

    General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. Weight 480 g 147 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 148 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100/1000 Mbps (full duplex) Transmission length up to 80 km (Depending on the fiber/SFP module used) 148 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 149 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 149 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 150: Fl Switch 2408

    DIN rail Weight 610 g Housing material Stainless steel 1.4301 MAC address table Signal contact Output name Relay Actuation voltage range max. 60 V DC Current carrying capacity max. 0.2 A 150 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 151 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A 151 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 152: Fl Switch 2408 Pn

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 152 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 153 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 160 mA (at U = 24 V DC and 25 °C ambient temperature) 153 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 154: Fl Switch 2406-2Sfx

    CSA C22.2 NO. 61010-1-12, Ed. 3 5.41 FL SWITCH 2406-2SFX Ordering data Order designation FL SWITCH 2406-2SFX Order No. 1043414 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 128 mm Height 110 mm Depth 69 mm 154 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 155 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 155 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 156 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 156 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 157: Fl Switch 2406-2Sfx Pn

    Free from substances that could impair the application of coating General data Mounting type DIN rail Type AX Block design Functional earth ground The functional ground of the module is grounded when it is snapped onto a grounded DIN rail 157 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 158 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (depending on the SFP module used) 158 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 159: Fl Switch 2404-2Tc-2Sfx

    EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 5.43 FL SWITCH 2404-2TC-2SFX Ordering data Order designation FL SWITCH 2404-2TC-2SFX Order No. 1088853 Pcs./Pkt. 159 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 160 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 160 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 161 = 24 V DC and 25 °C ambient temperature) Max. current consumption 290 mA (U = min, T = max) Maximum power dissipation for nominal condition 5.44 W (U = max, T = max) Test section for one minute 500 V DC 161 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 162: Fl Switch 2416

    Dimensions (nominal sizes in mm) Width 214 mm Height 110 mm Depth 69 mm Ambient conditions Degree of protection IP20 Protection class III (VDE 0106) Degree of pollution Ambient temperature (operation) -40 °C ... 70 °C 162 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 163 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 163 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 164 EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 Further approvals 164 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 165: Fl Switch 2416 Pn

    DIN rail Weight 1010 g Housing material Stainless steel 1.4301 MAC address table Signal contact Output name Relay Actuation voltage range max. 60 V DC Current carrying capacity max. 0.2 A 165 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 166 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A 166 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 167: Fl Switch 2414-2Sfx

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 167 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 168 Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) Interface: SFP module Number of interfaces Connection method SFP ports 168 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 169 EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 169 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 170: Fl Switch 2414-2Sfx Pn

    DIN rail Weight 1050 g Housing material Stainless steel 1.4301 MAC address table Signal contact Output name Relay Actuation voltage range max. 60 V DC Current carrying capacity max. 0.2 A 170 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 171 = 24 V DC and 25 °C ambient temperature) Max. current consumption 440 mA (U = min, T = max) Maximum power dissipation for nominal condition 8.26 W (U = max, T = max) Test section for one minute 500 V DC 171 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 172: Fl Switch 2412-2Tc-2Sfx

    Dimensions (nominal sizes in mm) Width 214 mm Height 110 mm Depth 69 mm Ambient conditions Degree of protection IP20 Protection class III (VDE 0106) Degree of pollution Ambient temperature (operation) -40 °C ... 70 °C 172 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 173 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 173 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 174 Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A 174 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 175: Fl Switch 2508

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating 175 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 176 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 230 mA (at U = 24 V DC and 25 °C ambient temperature) 176 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 177: Fl Switch 2508/K1

    CSA C22.2 NO. 61010-1-12, Ed. 3 5.50 FL SWITCH 2508/K1 Ordering data Order designation FL SWITCH 2508/K1 Order No. 1215350 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 128 mm Height 110 mm Depth 69 mm 177 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 178 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 178 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 179: Fl Switch 2508 Pn

    EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 5.51 FL SWITCH 2508 PN Ordering data Order designation FL SWITCH 2508 PN Order No. 1089134 Pcs./Pkt. 179 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 180 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 180 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 181 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 181 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 182: Fl Switch 2506-2Sfp

    Type AX Block design Functional earth ground The functional ground of the module is grounded when it is snapped onto a grounded DIN rail Weight 650 g Housing material High-grade steel 1.4305 MAC address table 182 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 183 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 260 mA (at U = 24 V DC and 25 °C ambient temperature) 183 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 184: Fl Switch 2506-2Sfp/K1

    CSA C22.2 NO. 61010-1-12, Ed. 3 5.53 FL SWITCH 2506-2SFP/K1 Ordering data Order designation FL SWITCH 2506-2SFP/K1 Order No. 1215329 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 128 mm Height 110 mm Depth 69 mm 184 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 185 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 185 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 186 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 186 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 187: Fl Switch 2506-2Sfp Pn

    DIN rail Weight 650 g Housing material Stainless steel 1.4301 MAC address table Signal contact Output name Relay Actuation voltage range max. 60 V DC Current carrying capacity max. 0.2 A 187 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 188 = 24 V DC and 25 °C ambient temperature) Max. current consumption 350 mA (U = min, T = max) Maximum power dissipation for nominal condition 6.46 W (U = max, T = max) Test section for one minute 500 V DC 188 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 189: Fl Switch 2504-2Gc-2Sfp

    CSA C22.2 NO. 61010-1-12, Ed. 3 5.55 FL SWITCH 2504-2GC-2SFP Ordering data Order designation FL SWITCH 2504-2GC-2SFP Order No. 1088872 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 128 mm Height 110 mm Depth 69 mm 189 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 190 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 190 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 191 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 191 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 192: Fl Switch 2516

    Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) 192 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 193 Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100/1000 Mbps Transmission length 100 m (per segment) 193 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 194: Fl Switch 2516 Pn

    Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 5.57 FL SWITCH 2516 PN Ordering data Order designation FL SWITCH 2516 PN Order No. 1089205 Pcs./Pkt. 194 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 195 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 195 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 196 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 196 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 197: Fl Switch 2514-2Sfp

    Type AX Block design Functional earth ground The functional ground of the module is grounded when it is snapped onto a grounded DIN rail Weight 1050 g Housing material Stainless steel 1.4301 MAC address table 197 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 198 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 460 mA (at U = 24 V DC and 25 °C ambient temperature) 198 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 199: Fl Switch 2514-2Sfp Pn

    CSA C22.2 NO. 61010-1-12, Ed. 3 5.59 FL SWITCH 2514-2SFP PN Ordering data Order designation FL SWITCH 2514-2SFP PN Order No. 1089154 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 214 mm Height 110 mm Depth 69 mm 199 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 200 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 200 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 201 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 201 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 202: Fl Switch 2512-2Gc-2Sfp

    Type AX Block design Functional earth ground The functional ground of the module is grounded when it is snapped onto a grounded DIN rail Weight 1050 g Housing material Stainless steel 1.4301 MAC address table 202 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 203 Note on the connection method Auto negotiation and autocrossing Transmission physics Depending on the SFP module Transmission speed 10/100/1000 Mbps (full duplex) Transmission length up to 80 km (Depending on the fiber/SFP module used) 203 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 204: Fl Switch 2608

    EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 5.61 FL SWITCH 2608 Ordering data Order designation FL SWITCH 2608 Order No. 1106500 Pcs./Pkt. 204 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 205 M12 connector, (A-coded) Interface: Ethernet Number of interfaces Connection method M12 connectors, D-coded Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 205 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 206: Fl Switch 2608 Pn

    EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 5.62 FL SWITCH 2608 PN Ordering data Order designation FL SWITCH 2608 PN Order No. 1106616 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 60 mm Height 226 mm Depth 46 mm 206 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 207 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 180 mA (at U = 24 V DC and 25 °C ambient temperature) 207 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 208: Fl Switch 2708

    III (VDE 0106) Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % Permissible humidity (storage/transport) 5 % ... 95 % 208 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 209 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 209 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 210: Fl Switch 2708 Pn

    79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Free from substances that could impair the application of coating General data Mounting type Wall mounting Type AX Stand-alone Weight 1150 g Housing material Zinc die-cast 210 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 211 EN 61000-6-3 (conducted emissions) Class B Interference emission EN 61000-6-3 (conducted emissions) Class B Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 211 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 212: Fl Nat 2008

    246.55 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) MTTF 56.66 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) 212 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 213 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 213 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 214: Fl Nat 2208

    Free from substances that could impair the application of coating General data Mounting type DIN rail Type AX Book type Functional earth ground The functional ground of the module is achieved when the module is snapped onto the DIN rail. 214 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 215 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 185 mA (at U = 24 V DC and 25 °C ambient temperature) 215 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 216: Fl Nat 2304-2Gc-2Sfp

    Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 5.67 FL NAT 2304-2GC-2SFP Ordering data Order designation FL NAT 2304-2GC-2SFP Order No. 2702981 Pcs./Pkt. Dimensions (nominal sizes in mm) Width 45 mm Height 130 mm Depth 115 mm 216 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 217 Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.08 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.08 mm² 217 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 218 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 218 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 219 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 219 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 220 FL SWITCH 2000 / FL NAT 2000 220 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 221: A Appendix For Document Lists

    Supplying the switch using two voltage sources ......... 34 Figure 321: Basic circuit diagram for the signal contact ......... 35 Figure 322: Dimensions of the FL SWITCH 26xx/27xx devices ......36 Figure 323: Elements of the FL SWITCH 26xx/27xx devices ......... 36 221 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 222 FL NETWORK MANAGER with BootP/DHCP reservation list shown ....................48 Figure 44: “IP Address Request Listener” window ..........49 Figure 45: “Set IP Address” window with incorrect settings ......... 50 Figure 46: “Assign IP Address” window ............... 50 222 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 223: A 2 List Of Tables

    Pin assignment for the power supply via M12 connectors with marking “XD1” ..................38 Table 3-14: Pin assignment for the power supply via M12 connectors with marking “XD2” ..................39 Section 4 Table 4-1: Operating modes in Smart mode ............44 223 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 224 FL SWITCH 2000 / FL NAT 2000 224 / 226 PHOENIX CONTACT 108997_en_04...
  • Page 225 The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations.
  • Page 226 Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to: tecdoc@phoenixcontact.com 226 / 226 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
  • Page 228 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg, Germany Phone: +49 5235 3-00 Fax: +49 5235 3-41200 E-mail: info@phoenixcontact.com phoenixcontact.com...

This manual is also suitable for: