Mechanical tests
Vibration (operation)
Vibration (storage/transport)
Shock (operation)
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Approvals / Certificates
UL, USA
UL, Canada
Further approvals
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
Ambient conditions
Degree of protection
Protection class
Degree of pollution
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
108997_en_04
5.3

FL SWITCH 2008F

2g, according to IEC 60068-2-6
2g, criterion 1 according to IEC 60068-2-6
30g (EN 60068-2-27)
Conformance with EMC Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1
CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010-
1-12, Ed.3
cULus Listed, EAC
FL SWITCH 2008F
1106707
1
75 mm
105 mm
43 mm
IP30
III (VDE 0106)
2
0 °C ... 60 °C
-40 °C ... 85 °C
10 % ... 95 % (non-condensing)
Technical data
57 / 226