FL SWITCH 2000 / FL NAT 2000
Mechanical tests
Vibration (operation)
Vibration (storage/transport)
Shock (operation)
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Approvals / Certificates
UL, USA
UL, Canada
Further approvals
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
Ambient conditions
Degree of protection
Protection class
Degree of pollution
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
68 / 226
PHOENIX CONTACT
5.8

FL SWITCH 2205

2g, according to IEC 60068-2-6
2g, criterion 1 according to IEC 60068-2-6
30g (EN 60068-2-27)
Conformance with EMC Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-3 (conducted emissions) Class B
EN 61000-6-2 EN 61000-6-3 (noise emission) Class B
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1
CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010-
1-12, Ed.3
cULus Listed, EAC
FL SWITCH 2205
2702326
1
45 mm
130 mm
115 mm
IP20
III, VDE 0106
2
-40 °C ... 70 °C
-40 °C ... 85 °C
10 % ... 95 % (non-condensing)
10 % ... 95 % (non-condensing)