Interface: Ethernet (RJ45)
Number of interfaces
Connection method
Note on the connection method
Transmission physics
Transmission speed
Transmission length
Supply voltage
Supply voltage
Residual ripple
Supply voltage range
Typical current consumption
Max. current consumption
Maximum power dissipation for nominal condition
Test section
Mechanical tests
Mechanical tests
Vibration (operation)
Vibration (storage/transport)
Shock (operation)
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Ordering data
Order designation
Order No.
Pcs./Pkt.
108997_en_04
5.51
FL SWITCH 2508 PN
8
RJ45
Auto negotiation and autocrossing
Copper
10/100/1000 Mbps
100 m (per segment)
24 V DC (redundant)
3.6 V
(within the permitted voltage range)
PP
12 V DC ... 32 V DC
230 mA (at U
= 24 V DC and 25 °C ambient temperature)
S
490 mA (U
= min, T
S
amb
6.08 W (U
= max, T
S
amb
for one minute 500 V DC
Free fall in accordance with EN 61131-2
in acc. with IEC 60068-2-6: 5g, 150 Hz
5g, 150 Hz, in acc. with IEC 60068-2-6
30g (EN 60068-2-27)
Conformance with EMC Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
FL SWITCH 2508 PN
1089134
1
Technical data
= max)
= max)
PHOENIX CONTACT
179 / 226