Fl Nat 2304-2Gc-2Sfp - Phoenix Contact FL SWITCH 2000 Series Installation And Startup Manual

Table of Contents

Advertisement

FL SWITCH 2000 / FL NAT 2000
Supply voltage
Max. current consumption
Maximum power dissipation for nominal condition
Test section
Mechanical tests
Mechanical tests
Vibration (operation)
Vibration (storage/transport)
Shock (operation)
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Approvals / Certificates
ATEX
IECEx
UL, USA
UL, Canada
UL, USA/Canada
Further approvals
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
216 / 226
PHOENIX CONTACT
5.67

FL NAT 2304-2GC-2SFP

1.3 A (U
= Min, T
= Max, DO
S
amb
4.95 W (At U
= 9 V DC and 70°C ambient temperature)
S
for one minute 500 V DC
Free fall in accordance with EN 61131-2
in acc. with IEC 60068-2-6: 5g, 150 Hz
5g, 150 Hz, in acc. with IEC 60068-2-6
30g (EN 60068-2-27)
Conformance with EMC Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
II 3 G Ex ec IIC T4 Gc
Ex ec IIC T4 Gc
UL 60079-0, Ed.6 / UL 60079-7, Ed.5
CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, IIC T4
cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA
FL NAT 2304-2GC-2SFP
2702981
1
45 mm
130 mm
115 mm
= Max)
I
108997_en_04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fl nat 2000 seriesFl switch 2005Fl switch 2306-2sfpFl switch 2608Fl switch 2008Fl switch 2306-2sfp pn ... Show all

Table of Contents