Fl Switch 2016 - Phoenix Contact FL SWITCH 2000 Series Installation And Startup Manual

Table of Contents

Advertisement

Supply voltage
Supply voltage
Residual ripple
Supply voltage range
Typical current consumption
Max. current consumption
Maximum power dissipation for nominal condition
Test section
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
Ambient conditions
Degree of protection
Protection class
Degree of pollution
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
108997_en_04
5.4

FL SWITCH 2016

24 V DC (single)
3.6 V
(within the permitted voltage range)
PP
18 V DC ... 32 V DC
160 mA (at U
= 24 V DC and 25 °C ambient temperature)
S
0.26 A (At U
= 18 V DC and 60°C ambient temperature)
S
4.68 W (At U
= 18 V DC and 60°C ambient temperature)
S
for one minute 500 V DC
Conformance with EMC Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
FL SWITCH 2016
2702903
1
85 mm
130 mm
115 mm
IP20
III, VDE 0106
2
0 °C ... 60 °C
-40 °C ... 85 °C
10 % ... 95 % (non-condensing)
10 % ... 95 % (non-condensing)
Technical data
59 / 226
PHOENIX CONTACT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fl nat 2000 seriesFl switch 2005Fl switch 2306-2sfpFl switch 2608Fl switch 2008Fl switch 2306-2sfp pn ... Show all

Table of Contents