Conformity with EMC directives
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Approvals / Certificates
ATEX
IECEx
UL, USA
UL, Canada
UL, USA/Canada
Further approvals
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
Ambient conditions
Degree of protection
Protection class
Degree of pollution
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
Air pressure (storage/transport)
Free from substances that could impair the application of
coating
108997_en_04
5.22
FL SWITCH 2216
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
II 3 G Ex ec IIC T4 Gc
Ex ec IIC T4 Gc
UL 60079-0, Ed.6 / UL 60079-7, Ed.5
CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, IIC T4
cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA
FL SWITCH 2216
2702904
1
85 mm
130 mm
115 mm
IP20
III, VDE 0106
2
-40 °C ... 70 °C
-40 °C ... 85 °C
10 % ... 95 % (non-condensing)
10 % ... 95 % (non-condensing)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without
derating)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without
derating)
Yes
Technical data
105 / 226
PHOENIX CONTACT