FL SWITCH 2000 / FL NAT 2000
Supply voltage
Supply voltage
Residual ripple
Supply voltage range
Typical current consumption
Max. current consumption
Maximum power dissipation for nominal condition
Test section
Mechanical tests
Mechanical tests
Vibration (operation)
Vibration (storage/transport)
Shock (operation)
Conformity with EMC directives
Electromagnetic compatibility
Conducted noise emission
Interference emission
Immunity to burst
Immunity to EF
Immunity to ESD
Immunity to surge
Immunity to conducted interference
Ordering data
Order designation
Order No.
Pcs./Pkt.
Dimensions (nominal sizes in mm)
Width
Height
Depth
206 / 226
PHOENIX CONTACT
5.62
FL SWITCH 2608 PN
24 V DC (redundant)
3.6 V
(within the permitted voltage range)
PP
9 V DC ... 57 V DC
180 mA (at U
= 24 V DC and 25 °C ambient temperature)
S
0.52 A (U
= min, T
= max)
S
amb
4.68 W (U
= min, T
S
amb
for one minute 500 V DC
Free fall in accordance with EN 61131-2
in acc. with IEC 60068-2-6: 5g, 150 Hz
5g, 150 Hz, in acc. with IEC 60068-2-6
30g (EN 60068-2-27)
Conformance with EMC Directive 2014/30/EU
EN 61000-6-3 (conducted emissions) Class B
EN 61000-6-3 (conducted emissions) Class B
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
FL SWITCH 2608 PN
1106616
1
60 mm
226 mm
46 mm
= max)
108997_en_04