Operation Requirements - Peak PCAN-MicroMod FD User Manual

Hide thumbs Also See for PCAN-MicroMod FD:
Table of Contents

Advertisement

1 analog input for voltage monitoring up to 30 V, resolution 12 bits
2 frequency outputs
Low-side switches
Adjustable frequency range from 0 to 20 kHz
Completely configurable using the Windows program PCAN-MicroMod FD Config-
uration
4-bit rotary coding switch for setting the module ID
I/O Motherboard Analog 1
8 analog inputs
Resolution 16 bits
Measuring range adjustable: ±2.5 V, ±5 V, ±10 V, ±20 V
4 analog inputs
Resolution 12 bits
Measuring range 0 to 10 V
4 analog outputs
Resolution 12 bits
Voltage range adjustable: 0 to 5 V, 0 to 10 V
4 digital inputs
Pull-up or pull-down configurable

1.2 Operation Requirements

Power supply in the range of 8 to 30 V DC (connection via 10-pole spring terminal
strip)
For transfer of the configuration and for a firmware update (both via CAN):
1 Introduction
PCAN-MicroMod FD Analog 1
User Manual 1.2.0
© 2021 PEAK-System Technik GmbH