Analog Outputs
Count
Resolution D/A converter
Connectors
Voltage ranges (adjustable
by configuration)
Accuracy
Output current maximum
Protection
Digital Inputs
Count
Connectors
Input voltage maximum
Input impedance
Input circuitry
Switching thresholds Low →
High
Switching thresholds High →
Low
Low-pass
7 Technical Specifications
User Manual 1.2.0
© 2021 PEAK-System Technik GmbH
4
12 bit
AOut_0 ... AOut_3
0 – 5 V
± 0.3 %
± 2.5 mV
20 mA
Short circuit protection
4
DIn_0 ... DIn_3
+50 V
69 kΩ (without pull-up and pull-down)
Set per input by configuration:
- Open
- Pull-up: 4.7 kΩ to supply voltage
- Pull-down: 4.7 kΩ to ground
> 5.8 V typ. (4.5 V – 7.5 V)
< 3.5 V typ. (2.2 V – 4.5 V)
f
= 3 kHz
g
PCAN-MicroMod FD Analog 1
0 – 10 V
± 0.2 %
± 5 mV